S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
151 IS 10632 : Part 3 (1983) Specification for non magnetic stainless steels for electrical applications: Part 3 specific requirements for sheets, strips and plates - - View breakup
-
- -
Test facilities are not available for the following: (1) Electric Resistivity (2)Mangentic property 3) Chemical composition (Ni, Cr, Co, Mo, Cu, Fe)
152 IS 10632 : Part 2 (1983) Specification for non magnetic stainless steels for electrical applications: Part 2 specific requirements for binding wires - - View breakup
-
- -
Test facilities are not available for the following: (1) Electric Resistivity (2)Mangentic property 3) Chemical composition (Ni, Cr, Co, Mo, Cu, Fe)
153 IS 15911 (2010) Structural steel (Ordinary Quality) - Specification - Rs 6750/- For elements other than Table-1: Rs 1004/- pe View breakup
-
- -
Test facilities are not available for the following: 1. Microalloying elements, Mn, Al, Ni, Cu, Cr, Mo, N
154 IS 10631 (1983) Specification for stainless steel for welding electrode core wire - - View breakup
-
- -
Test facilities are not available for the following: 1. Cr, Ni, Mo
155 IS 1029 (1970) Specification for hot-rolled steel strip (Baling) (First Revision) - Rs.750/- View breakup
-
- -
-
156 IS 15961 (2012) Hot dip aluminium - Zinc alloy metallic coated steel strip and sheet (Plain) - Rs.4990 View breakup
-
- -
-
157 IS 15778 (2007) Chlorinated polyvinyl chloride (Cpvc) pipes for potable hot and cold water distribution supplies - Specification - 6375 View breakup
-
- -
The following test facilities are not available: (1) Verification of the Malfunction temperature Cl 6.3.2 (2) Effect on water Cl.9.3 (3) Hyd. characteristics Cl.10.1 for 165 Hr and 1000 Hr (4) thermal stability test.Cl.10.2
158 IS 15328 (2003) Unplasticized Non-Pressure Polyvinyl Chloride ( PVC -U ) Pipes for use in Underground Drainage and Sewerage Systems - - 3450 View breakup
-
- -
The following test facilities are not available: (1) Ring Stiffness (2)Elastomeric Sealing ring (3)Internal Hydrostatic Pressure for sealing ring joints (4)Intenal negative hydrostatic pressure set up. (5)Effect on water (6) TF above 250 mm
159 IS 14899 (2014) Liquefied petroleum gas (LPG) containers for automotive use - Specification (First Revision) - 21363 View breakup
-
- -
Test facilities are not available for the following: (1) ( Cl. 10.5.1) - Radiographic examinations, (2) (Cl.10.6.1) Bonfire test, (3) (Cl.10.6.3) - Crash test, (4) (cl.10.6.2) - Fatigue Test (5) Chemical composition( Ni, Cr, N )
160 IS 13997 (2014) Drums, large open top - Specification (First Revision) - - View breakup
-
- -
-
161 IS 13983 (1994) Stainless Steel Sinks For Domestic Purposes - Rs.14635/- View breakup
-
- -
Test facilities are not available for the following: 1. Ni, Cr, Nitrogen as per IS 5522
162 IS 13487 (1992) Irrigation equipment - Emitters - Specification - Rs.4200/- View breakup
-
- -
-
163 IS 13422 (1992) Disposable surgical rubber gloves specification - Rs.6900.00 View breakup
-
- -
-
164 IS 15962 (2012) Structural steels for buildings and structures with improved seismic resistance - - View breakup
-
- -
Test facilities are not available for the following: 1. Chemical Composition ( Cr, Mo, Ni, Al, Microalloying element, N, Cu)
165 IS 14735 (1999) Unplasticized Polyvinyl Chloride (UPVC) Injection Moulded Fittings for Soil and Waste Discharge System for Inside and Outside Buildings Including Ventilation and Rain Water System - - Total Testing Charges : Rs. 9970.00 View breakup
-
- -
Remark : a sealing ring-prepared button piece is required to measure the IRHD harness.
166 IS 12337 (1988) Specification for manually operated fertilizer broadcaster - Rs 600/- View breakup
-
- -
-
167 IS 15997 (2012) Low nickel austenitic stainless steel sheet and strip for utensils and kitchen appliances - Specification - Rs 2850 View breakup
-
- -
Test facilities are not available for the following: 1. Ni, Cr, Cu, N, 2. Erichsen Cuppling Machine
168 IS 11313 (2007) Hydraulic power sprayers - Specification (First Revision) - 13350 View breakup
-
- -
-
169 IS 10124 : Part 2 (2009) Fabricated pvc - U fittings for potable water supplies - Specification: Part 2 specific requirements for sockets (Second Revision) - Rs.1800/ View breakup
-
- -
The following test facilities are not available: (1)Effect on water (2) Testing facility above 250 mm for Short Term Hydrostatic test
170 IS 10124 : Part 1 (2009) Fabricated PVC-U Fittings for Potable Water Supplies - Specification Part 1 General Requirements (Second Revision) - Rs 1500/- View breakup
-
- -
The following test facilities are not available: (1)Effect on water (2) Testing facility above 250 mm for Short Term Hydrostatic test
171 IS 9798 (2013) Low pressure regulators for use with liquefied petroleum gas (LPG) - Specification (Second Revision) - 14276 View breakup
-
- -
Test facilities are not available for the following: a) Mechanical strength of connections, Cl. 8.11 b) Compression set test for Rubber components c) Test Bench as per Annex K
172 IS 9295 (1983) Specification for steel tubes for idlers for belt conveyors (First Revision) - Rs 5100/- View breakup
-
- -
Test facilities are not available for the following: 1.Except Drift Expansion
173 IS 8737 (2017) Valve fittings for use with liquefied petroleum gas (LPG) cylinders for more than 5 litre water capacity - Specification (Second Revision) - - View breakup
-
- -
"1.Cycles test 2. Security Cap /Nut 3. Spring a) Load Test b)Permanent set test c)Rust proofness of spring"
174 IS 8423 (1994) Specification for controlled percolating hose for fire fighting - Rs. 4200/- View breakup
-
- -
-
175 IS 7887 (1992) Mild steel wire rod for general engineering purposes - Specification (First Revision) - Rs.7200/- View breakup
-
- -
Test facilities are not available for the following: 1. Chemical composition (Al)
176 IS 7834 : Part 3 (1987) injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 3 Specific requirements for 90 degree elbows - Rs.2700/- View breakup
-
- -
The following test facilities are not available: 6.3 Effect on water
177 IS 7834 : Part 1 (1987) injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 1 General requirements - Rs.2400/- View breakup
-
- -
The following test facilities are not available: 6.3 Effect on water
178 IS 15490 (2017) Seamless steel cylinders for on - Board storage of compressed natural gas as a fuel for automotive vehicles - Specification (First Revision) - 16297 View breakup
-
- -
Test facilities are not available for the following: 1. Cr, Ni, Mo, V, Al, N, B, Zr 2.Pressure cycling Test 3. Base check 4. Hydrostatic Stretch Test 5. Leakage Test 6.Neck threads 7. Surface Defects 8. Verticality 9. Hydraulic Bursting Test 10. Sulphide Stress Cracking Resistance Test 11 Ultrasonic testing 12 Leakage before breakage test 13 Bonfire test Remark: Prepared piece for tensile (2 nos), bend (4 nos) and impact (3 nos)
179 IS 7285 : Part 1 (2018) Refillable seamless steel gas cylinders - Specification: Part 1 normalized steel cylinders (Fourth Revision) - - View breakup
-
- -
Test facilities are not available for the following: 1. Cr, Ni, Mo, V, Al, N, B, Zr 2.Pressure cycling Test 3. Base check 4. Hydrostatic Stretch Test 5. Leakage Test 6.Neck threads 7. Surface Defects 8. Verticality 9. Hydraulic Bursting Test 10. Sulphide Stress Cracking Resistance Test 11 Ultrasonic testing Remark: Prepared piece for tensile (2 nos), bend (4 nos) and impact (3 nos)
180 IS 7142 (1995) Welded low carbon steel cylinders for low pressure liquifiable gases not exceeding 5 litre water capacity - Specification (First Revision) - Rs. 9552/- View breakup
-
- -
Test facilities are not available for the following: 1. Thread gauges