BIS, Western Regional Laboratory (WRL)

BUREAU OF INDIAN STANDARDS (WESTERN REGIONAL LABORATORY), PLOT NO. E9, ROAD NO. 8, M.I.D.C, ANDHERI (EAST), MUMBAI, MAHARASHTRA, INDIA, MUMBAI, Mumbai Suburban, Maharashtra, 400093
- wrol@bis.gov.in
Scope List
Reset
246 Results
S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
151 IS 13997 (2014) Drums, large open top - Specification (First Revision) - - View breakup
-
- -
-
152 IS 13983 (1994) Stainless Steel Sinks For Domestic Purposes - Rs.14635/- View breakup
-
- -
Test facilities are not available for the following: 1. Ni, Cr, Nitrogen as per IS 5522
153 IS 13487 (1992) Irrigation equipment - Emitters - Specification - Rs.4200/- View breakup
-
- -
-
154 IS 13422 (1992) Disposable surgical rubber gloves specification - Rs.6900.00 View breakup
-
- -
-
155 IS 13098 (2012) Automotive vehicles - Tubes for pneumatic tyres - Specification (First Revision) - Total Resting Charges : Rs. 13,050.00 View breakup
-
- -
Remark 1: To carry out fit & form test type is required of the relevant size of tube.
156 IS 15962 (2012) Structural steels for buildings and structures with improved seismic resistance - - View breakup
-
- -
Test facilities are not available for the following: 1. Chemical Composition ( Cr, Mo, Ni, Al, Microalloying element, N, Cu)
157 IS 12586 (1988) Brazed low carbon steel gas cylinders not exceeding 13 litre water capacity - Specification - Rs 8670/- View breakup
Rs 8670/- + charges as per relevant ISS excluding material test.
- -
Test facilities are not available for the following: a) Peel Test
158 IS 14735 (1999) Unplasticized Polyvinyl Chloride (UPVC) Injection Moulded Fittings for Soil and Waste Discharge System for Inside and Outside Buildings Including Ventilation and Rain Water System - - Total Testing Charges : Rs. 9970.00 View breakup
-
- -
Remark : a sealing ring-prepared button piece is required to measure the IRHD harness.
159 IS 12337 (1988) Specification for manually operated fertilizer broadcaster - Rs 600/- View breakup
-
- -
-
160 IS 15997 (2012) Low nickel austenitic stainless steel sheet and strip for utensils and kitchen appliances - Specification - Rs 2850 View breakup
-
- -
Test facilities are not available for the following: 1. Ni, Cr, Cu, N, 2. Erichsen Cuppling Machine
161 IS 11313 (2007) Hydraulic power sprayers - Specification (First Revision) - 13350 View breakup
Rs 13350/- + charges as per relevant ISS excluding material test.
- -
-
162 IS 10124 : Part 2 (2009) Fabricated pvc - U fittings for potable water supplies - Specification: Part 2 specific requirements for sockets (Second Revision) - Rs.1800/ View breakup
Rs.1800/- and Material testing charges as per relevant referred Iss
- -
The following test facilities are not available: (1)Effect on water (2) Testing facility above 250 mm for Short Term Hydrostatic test
163 IS 10124 : Part 1 (2009) Fabricated PVC-U Fittings for Potable Water Supplies - Specification Part 1 General Requirements (Second Revision) - Rs 1500/- View breakup
-
- -
The following test facilities are not available: (1)Effect on water (2) Testing facility above 250 mm for Short Term Hydrostatic test
164 IS 9798 (2013) Low pressure regulators for use with liquefied petroleum gas (LPG) - Specification (Second Revision) - 14276 View breakup
Rs. 14276/- + testing charges as per referred ISS (excluding excess flow valve and strength on inlet connection).
- -
Test facilities are not available for the following: a) Mechanical strength of connections, Cl. 8.11 b) Compression set test for Rubber components c) Test Bench as per Annex K
165 IS 9295 (1983) Specification for steel tubes for idlers for belt conveyors (First Revision) - Rs 5100/- View breakup
-
- -
Test facilities are not available for the following: 1.Except Drift Expansion
166 IS 8737 (2017) Valve fittings for use with liquefied petroleum gas (LPG) cylinders for more than 5 litre water capacity - Specification (Second Revision) - - View breakup
-
- -
"1.Cycles test 2. Security Cap /Nut 3. Spring a) Load Test b)Permanent set test c)Rust proofness of spring"
167 IS 8423 (1994) Specification for controlled percolating hose for fire fighting - Rs. 4200/- View breakup
-
- -
-
168 IS 7887 (1992) Mild steel wire rod for general engineering purposes - Specification (First Revision) - Rs.7200/- View breakup
-
- -
Test facilities are not available for the following: 1. Chemical composition (Al)
169 IS 7834 : Part 3 (1987) injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 3 Specific requirements for 90 degree elbows - Rs.2700/- View breakup
-
- -
The following test facilities are not available: 6.3 Effect on water
170 IS 7834 : Part 1 (1987) injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 1 General requirements - Rs.2400/- View breakup
-
- -
The following test facilities are not available: 6.3 Effect on water
171 IS 15490 (2017) Seamless steel cylinders for on - Board storage of compressed natural gas as a fuel for automotive vehicles - Specification (First Revision) - 16297 View breakup
-
- -
Test facilities are not available for the following: 1. Cr, Ni, Mo, V, Al, N, B, Zr 2.Pressure cycling Test 3. Base check 4. Hydrostatic Stretch Test 5. Leakage Test 6.Neck threads 7. Surface Defects 8. Verticality 9. Hydraulic Bursting Test 10. Sulphide Stress Cracking Resistance Test 11 Ultrasonic testing 12 Leakage before breakage test 13 Bonfire test Remark: Prepared piece for tensile (2 nos), bend (4 nos) and impact (3 nos)
172 IS 7285 : Part 1 (2018) Refillable seamless steel gas cylinders - Specification: Part 1 normalized steel cylinders (Fourth Revision) - - View breakup
-
- -
Test facilities are not available for the following: 1. Cr, Ni, Mo, V, Al, N, B, Zr 2.Pressure cycling Test 3. Base check 4. Hydrostatic Stretch Test 5. Leakage Test 6.Neck threads 7. Surface Defects 8. Verticality 9. Hydraulic Bursting Test 10. Sulphide Stress Cracking Resistance Test 11 Ultrasonic testing Remark: Prepared piece for tensile (2 nos), bend (4 nos) and impact (3 nos)
173 IS 7142 (1995) Welded low carbon steel cylinders for low pressure liquifiable gases not exceeding 5 litre water capacity - Specification (First Revision) - Rs. 9552/- View breakup
-
- -
Test facilities are not available for the following: 1. Thread gauges
174 IS 7092 : Part 2 (1987) Specification for aluminium alloy tube for irrigation purposes: Part 2 extruded tube (Second Revision) - Rs 11230/- View breakup
-
- -
" 1. Tensile Test 2. Hydrostatic Machine "
175 IS 6603 (2001) Stainless steel bars and flats - Specification (First Revision) - - View breakup
-
- -
Test facilities are not available for the following: 1. Ti, Nb, Mo, Cu 2. Corrosion resistance Remark: Prepared piece of impact (3 nos)
176 IS 6529 (1996) Stainless steel blooms, billets and slabs for forging - Specification (First Revision) - - View breakup
-
- -
Test facilities are not available for the following: 1. Ni, Cr, Mo, Ti, Nb, N 2. Corrosion Test
177 IS 14333 (1996) High Density Polyethylene Pipe For Sewerage - - 3900 View breakup
-
- -
The following test facilities are not available: (1)Internal Pressure creep rupture test (2)Tensile Strength for Butt-fusion (3) Slow Crack Growth rate test (4) Depth of strip (5) Overall Migration (7) Carbon Black content (8) For Size above 250 mm
178 IS 6240 (2008) Hot rolled steel plate (Up To 6 Mm) sheet and strip for the manufacture of low pressure liquefiable gas cylinders (Fourth Revision) - 9710 View breakup
Rs.9710/- excluding Erichsen cupping test.
- -
Test facilities are not available for the following: 1. Al, N, Micro alloying element 2. Erichsen Cuppling Machine
179 IS 11513 (2017) Hot rolled carbon steel strip for cold rolling purposes - Specification (Second Revision) - - View breakup
-
- -
Test facilities are not available for the following: 1. Micro alloy, N, Al, Cu, Cr, Mo, Ni
180 IS 4923 (2017) Hollow steel sections for structural use - Specification (Third Revision) - - View breakup
-
- -
Test facilities are not available for the following: 1. Cu

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in