| 61 |
IS 8034 (2018) |
Submersible pumpsets - Specification (Third Revision) |
Voltage: up to 440V Rated power: up to110 kW, Size: 6'' |
53100 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1 (a)(Constructional Features) |
- |
3000 |
|
- |
| 6.1 (b)(Constructional Features) |
- |
3000 |
|
- |
| 6.1 (c)(Constructional Features) |
- |
3000 |
|
- |
| 6.1 (d)(Constructional Features) |
- |
3000 |
|
- |
| 6.1 (e)(Constructional Features) |
- |
3000 |
|
- |
| 6.1 (f)(Constructional Features) |
- |
3000 |
|
- |
| 6.2 (a)(Material of construction Part Sub Assembly
Shaft Sleeve) |
- |
3000 |
|
- |
| 6.2 (b)(Material of construction Part Sub Assembly
Casing wear ring
(if provided)) |
- |
3000 |
|
- |
| 6.2 (c)(Material of construction Part Sub Assembly
Bush) |
- |
3000 |
|
- |
| 6.2 (d)(Material of construction Part Sub Assembly
Discharge casing
(if provided)) |
- |
3000 |
|
- |
| 6.2 (e)(Material of construction Part Sub Assembly
Impeller) |
- |
3000 |
|
- |
| 6.2 (f)(Material of construction Part Sub Assembly
Pump Bowl/Diffuser) |
- |
3000 |
|
- |
| 6.2 (g)(Material of construction Part Sub Assembly
Pump Shaft) |
- |
3000 |
|
- |
| 6.2 (h)(Material of construction Part Sub Assembly
Suction Casing) |
- |
3000 |
|
- |
| 6.2.2.1(Gaskets, Seals and Packings) |
- |
3000 |
|
- |
| 6.2.2.2(Gaskets, Seals and Packings) |
- |
3000 |
|
- |
| 6.2.3(Gaskets, Seals and Packings) |
- |
3000 |
|
- |
| 6.2.4(Gaskets, Seals and Packings) |
- |
3000 |
|
- |
| 6.2.5(Gaskets, Seals and Packings) |
- |
3000 |
|
- |
| 7.1.1(Design features:
Typical design features 0f components of pump) |
- |
0 |
|
- |
| 7.1.2(Design features:
Typical design features 0f components of pump) |
- |
0 |
|
- |
| 7.1.3(Design features:
Typical design features 0f components of pump) |
- |
0 |
|
- |
| 7.1.4(Design features:
Typical design features 0f components of pump) |
- |
0 |
|
- |
| 7.1.5(Design features:
Typical design features 0f components of pump) |
- |
0 |
|
- |
| 7.1.6(Design features:
Typical design features 0f components of pump) |
- |
0 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 14(Marking) |
- |
500 |
|
- |
| 8.3(Impeller) |
- |
0 |
|
- |
| 8.4.1(Shaft) |
- |
0 |
|
- |
| 8.4.2(Shaft) |
- |
800 |
|
- |
| 8.5.1(Balancing) |
- |
2700 |
|
- |
| 8.5.2(Balancing) |
- |
2700 |
|
- |
| 8.7.1(Direction of Rotation) |
- |
400 |
|
- |
| 8.7.2(Direction of Rotation) |
- |
400 |
|
- |
| 8.8(Terminal Marking) |
- |
0 |
|
- |
| 8.9.1(Typical Installation) |
- |
500 |
|
- |
| 8.9.3(Typical Installation) |
- |
500 |
|
- |
| 10.3(Hydrostatic Pressure Test) |
- |
2300 |
|
- |
| 11.1.1(Guarantee of Performance) |
- |
0 |
|
- |
| 11.1.2(Guarantee of Performance) |
- |
0 |
|
- |
| 11.1.2(Guarantee of Performance) |
- |
0 |
|
- |
| 11.1.3(Guarantee of Performance) |
- |
0 |
|
- |
| 11.1.4(Guarantee of Performance) |
- |
0 |
|
- |
| 11.1.5(Guarantee of Performance) |
- |
0 |
|
- |
| 8.6(Submersible cable) |
- |
700 |
|
- |
| 7.1.10(Voltage & Frequency variation) |
- |
0 |
|
- |
| 10(Pump Performance test) |
- |
12000 |
|
- |
| 11(Guarantee of Performance) |
- |
0 |
|
- |
| 9.10 (a)(Insulation Resistance test) |
- |
550 |
|
- |
| 9.10 (b)(High Voltage test) |
- |
550 |
|
- |
| 9.10 (c)(Measurement of Stator Resistance) |
- |
500 |
|
- |
| 9.10 (d)(No Load Test at Rated Voltage) |
- |
1200 |
|
- |
| 9.10 (e)(Reduced voltage Running up test) |
- |
800 |
|
- |
| 9.10 (f) & (g)(Locked Rotor Test) |
- |
3000 |
|
- |
| 9.10 (h)(Leakage current test) |
- |
1000 |
|
- |
| 9.10 (j)(Temperature Rise Test at Rated Voltage) |
- |
12000 |
|
- |
| 9.10 (k)(Temperature rise test at reduced voltage) |
- |
9000 |
|
- |
| 8.6.1(Flat/Round cables as per IS694 shall be used) |
- |
0 |
|
- |
| 8.6.2(The size of the conductor shall be adequate and suitable for contineous use under water and in air.
the length of the cable shall be minimum 2 m externallly unless otherwise specified by the customer) |
- |
0 |
|
- |
| 8.6.3(The size and of the cable should be suitably selected so that the voltage drop between control panel and the mptor terminal does not
exeed three percent of the rated voltage) |
- |
0 |
|
- |
| 8.6.4(In case a joint is required to be made between the lead cable supplied with the motor and the user’s cable, a detailed procedure to
make water tight joining shall be supplied by the motor manufacturer.) |
- |
0 |
|
- |
| 8.9.4.1(Earthing of the motor shall be done as per IS 9283 in accordance with the relevant provisions of IS 3043.) |
- |
400 |
|
- |
| 8.9.4c(Earthing) |
- |
500 |
|
- |
|
30 Nov, 2028 |
- - |
| 62 |
IS 9079 (2018) |
Monoset pumps for clear, cold water for agricultural and water supply purposes - Specification (Third Revision) |
Voltage: up to 440 V Power: up to 110 kW, Size: 5” |
46346 View breakup
Up to 5.5kW : Rs. 8,875/- ;
5.5 kW to 11kW : Rs. 9,918/- ;
11 kW to 22 kW : Rs. 17,295/- ;
22.1 kW to 45 kW : Rs. 30,039/- ;
45.1 kW to 75 kW : Rs. 37,606/- ;
75.1 kW to 110 kW : Rs. 46,346/- .
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1(GENERAL REQUIREMENTS
Casing) |
- |
1725 |
|
Nil |
| 10.2(GENERAL REQUIREMENTS
Impeller) |
- |
0 |
|
Nil |
| 10.3(GENERAL REQUIREMENTS
Shaft) |
- |
0 |
|
Nil |
| 9.1(DESIGN
FEATURES (Cl 9)) |
- |
0 |
|
Nil |
| 9.2(DESIGN
FEATURES (Cl 9)) |
- |
0 |
|
Nil |
| 7.1(Material of Construction) |
- |
0 |
|
Nil |
| 7.2(Gaskets.Seals and packings) |
- |
0 |
|
Nil |
| 9.1.1(The pump may be equipped with replaceable bearing and wearing ring, wherever provided.) |
- |
0 |
|
Nil |
| 9.1.2(The pump shall be capable to perform as per guaranteed duty point at the manometric suction lift as specified in Table 1.) |
- |
0 |
|
Nil |
| 9.4(The pump efficiency of monoset pumps at duty point as declared by the manufacturer for 2 and 4 poles shall not be less than given in
Fig. 3 to Fig. 6 and beyond this range, the efficiency shall be declared by manufacturer.) |
- |
0 |
|
Nil |
| 10.4.1, 10.4.2, 10.4.3, 10.4.4(General Requirements(Balancing)) |
- |
4600 |
|
Nil |
| 10.5(Provision of Earthing) |
- |
0 |
|
Nil |
| 10.6.2, 10.6.3(Direction of Rotation) |
- |
863 |
|
Nil |
| 11.8.1(a)(Measurement of stator resistance) |
- |
690 |
|
Nil |
| 11.8.1(b)(High Voltage test) |
- |
1380 |
|
Nil |
| 11.8.1(c)(Insulation Resistance test) |
- |
1380 |
|
Nil |
| 11.8.1(d)(No load test at rated voltage) |
- |
1380 |
|
Nil |
| 11.8.1(e)(Locked rotor) |
- |
3450 |
|
Nil |
| 11.8.1(g)(Reduced voltage running up test at no load) |
- |
863 |
|
Nil |
| 11.8.1(h)(Temperature rise test at rated voltage) |
- |
11500 |
|
Nil |
| 11.8.1(j)(Temperature rise test at reduced voltage) |
- |
9200 |
|
Nil |
| 13.1.3(Monoset motor shall not get overloaded in the specified operating head range at rated voltage and supply frequency.) |
- |
8625 |
|
Nil |
| 10.6.1(Terminal Marking) |
- |
0 |
|
Nil |
| 13.1(Guarantee and tolerances on Pump Performance (Cl 13)) |
- |
8625 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 15.1(Marking) |
- |
690 |
|
Nil |
| 13.5(Minimum Current Requirement) |
- |
8625 |
|
Nil |
|
30 Nov, 2028 |
- - |
| 63 |
IS 1576 (1992) |
Solid pressboard for electrical purposes - Specification (First Revision) |
Grade: A, B, C and D |
32200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.No.5.2(Thickness) |
- |
575 |
|
Same as above |
| Cl.No.5.4(Density) |
- |
1150 |
|
Same as above |
| Cl.No.5.5.1(Electric Strength (Proof Test) in air at 90°C) |
- |
3450 |
|
Same as above |
| Cl.No.5.5.2(Electric Strength (Proof Test) in Oil at 90°C) |
- |
4600 |
|
Same as above |
| Cl.No.5.6(Tensile Strength) |
- |
1150 |
|
Same as above |
| Cl.No.5.8.1(Shrinkage in air) |
- |
2300 |
|
Same as above |
| Cl.No.5.8.2(Shrinkage in Oil) |
- |
5750 |
|
Same as above |
| Cl.No.5.9(Flexibility) |
- |
575 |
|
Same as above |
| Cl.No.5.10(Cohesion between Piles) |
- |
575 |
|
Same as above |
| Cl.No.5.11(Oil Absorption) |
- |
3450 |
|
Same as above |
| Cl.No.5.12(Machinability) |
- |
575 |
|
Same as above |
| Cl.No.5.13(Conductivity of aqueous extract) |
- |
1725 |
|
Same as above |
| Cl.No.5.14(pH of aqueous extract) |
- |
1725 |
|
Same as above |
| Cl.No.5.15(Moisture Content) |
- |
2875 |
|
Same as above |
| Cl.No.5.16(Mineral Ash) |
- |
1725 |
|
Same as above |
|
30 Nov, 2028 |
- - |
| 64 |
IS 9857 (1990) |
Welding cables - Specification (First Revision) |
- |
28300 View breakup
Rs. 28,300/- (for type test) ;
Multicore cables: additional charges Rs. 500/- per core per test.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1 a) 1)(Annealing test - IS 10810: Part 1) |
- |
600 |
|
- |
| 10.1 a) 2)(Conductor resistance tes - IS 10810 : Part 5) |
- |
700 |
|
- |
| 9.2(T h i c k n e s s o f C o v e r i n g) |
- |
1200 |
|
- |
| 10.1 c) 1)(Physical tests for
covering : Tensile strength ) |
- |
400 |
|
- |
| 10.1 c) 1)(Physical tests for
covering : Elongation at break ) |
- |
400 |
|
- |
| 10.1 c) 2)(Physical tests for
covering - Ageing in Air oven : Tensile strength variation) |
- |
1588 |
|
- |
| 10.1 c) 2)(Physical tests for
covering -Ageing in Air oven : Elongation at break ) |
- |
1588 |
|
- |
| 10.1 c) 2)(Physical tests for
covering - Ageing in Air oven : Tensile strength ) |
- |
1588 |
|
- |
| 10.1 c) 2)(Physical tests for
covering -Ageing in Air oven : Elongation variation at break ) |
- |
1588 |
|
- |
| 10.1 c) 3)(Physical tests for
covering - Ageing in Air Bomb : Tensile strength variation ) |
- |
1150 |
|
- |
| 10.1 c) 3)(Physical tests for
covering -Ageing in Air Bomb : Elongation variation at break ) |
- |
1150 |
|
- |
| 10.1 c) 4)(Physical tests for
covering - Oil Resistance : Tensile strength variation ) |
- |
950 |
|
- |
| 10.1 c) 4)(Physical tests for
covering - Oil Resistance : Elongation variation at break ) |
- |
950 |
|
- |
| 10.1 c) 5)(Hot set test ) |
- |
550 |
|
- |
| 10.1 c) 5)(Permanent set ) |
- |
550 |
|
- |
| 11.1(High Voltage Test ( Water Immersion
Test )) |
- |
900 |
|
- |
| 11.3(Static Flexibility Test) |
- |
850 |
|
- |
| 11.4(Flammability Test) |
- |
950 |
|
- |
| 7(CONDUCTOR : CONSTRUCTION ) |
- |
1550 |
|
- |
|
30 Nov, 2028 |
- - |
| 65 |
IS 4289 : Part 2 (2000) |
Flexible cables for lifts and other flexible connections - Specification: Part 2 pvc insulated circular cables |
- |
37900 View breakup
Type tests Rs. 37,900/- ;
Multicore cables: additional charges Rs. 500/- per core per test.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 14.2(Thickness of Insulation) |
- |
500 |
|
NA |
| 14.3(Tolerance on Thickness of Insulation) |
- |
500 |
|
NA |
| 17.1.1(Thickness of Sheath) |
- |
500 |
|
NA |
| 17.1.2(Tolerance on Thickness of Sheath) |
- |
500 |
|
NA |
| 18.1.a.i(IS 10810 Part-1) |
- |
- |
|
- |
| 18.1.a.ii(IS 10810 Part-5) |
- |
- |
|
- |
| 18.1.b(IS 10810 Part-6) |
- |
- |
|
- |
| 18.1.c.i(IS 10810 Part-7) |
- |
- |
|
- |
| 18.1.c.i(IS 10810 Part-7) |
- |
- |
|
- |
| 18.1.c.ii(IS 10810 Part-11) |
- |
- |
|
- |
| 18.1.c.ii(IS 10810 Part-11) |
- |
- |
|
- |
| 18.1.c.iii(IS 10810 Part-10) |
- |
- |
|
- |
| 18.1.c.iii(IS 10810 Part-10) |
- |
- |
|
- |
| 18.1.c.iv(IS 10810 Part-14) |
- |
- |
|
- |
| 18.1.c.iv(IS 10810 Part-14) |
- |
- |
|
- |
| 18.1.c.v(IS 10810 Part-12) |
- |
- |
|
- |
| 18.1.c.v(IS 10810 Part-12) |
- |
- |
|
- |
| 18.1.c.vi(IS 10810 Part-60) |
- |
- |
|
- |
| 18.1.c.vi(IS 10810 Part-60) |
- |
- |
|
- |
| 18.1.d(IS 10810 Part-45) |
- |
- |
|
- |
| 18.1.e(IS 10810 Part-43) |
- |
- |
|
- |
| 18.1. f(IS 10810 Part-54) |
- |
- |
|
- |
| 18.1.g(IS 10810 Part-53) |
- |
- |
|
- |
|
30 Nov, 2028 |
- - |
| 66 |
IS 8783 : Part 4 : Sec 2 (1995) |
Winding wires for submersible motors - specification: Part 4 specification for individual wires: Sec 2 crosslinked polyethylene insulated and polyamide jacketed wires (First Revision) |
- |
20750 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Thickness of insulation) |
- |
1200 |
|
- |
| 4.3(Colour) |
- |
0 |
|
- |
| 4.4(Overall diameter) |
- |
500 |
|
- |
| 4.6(High voltage test) |
- |
900 |
|
- |
| 4.6(High Voltage Test (Water Immersion ) ) |
- |
900 |
|
- |
| Table 1, Cl.4.1, Cl.4.4(Conductor diameter) |
- |
500 |
|
- |
| Table 1, Cl.4.1, Cl.4.4(Thickness of PA jacket) |
- |
1200 |
|
- |
| 3.2(Requirements(Cl. 4 Table
1 of IS: 8783 (part 2) Heat shock Test) |
- |
800 |
|
- |
| 3.2(Requirements(Cl. 4 Table
1 of IS: 8783 (part 2) Hot deformation Test ) |
- |
1200 |
|
- |
| 3.2(Requirements(Cl. 4 Table
1 of IS: 8783 (part 2) Water absorption) |
- |
1850 |
|
- |
| 3.2(Requirements(Cl. 4 Table
1 of IS: 8783 (part 2) Shrinkage Test) |
- |
400 |
|
- |
| 3.2(Requirements(Cl. 4 Table
1 of IS: 8783 (part 2) Shrinkage Test) |
- |
400 |
|
- |
| 3.2(Requirements(Cl. 4 Table
1 of IS: 8783 (part 2) Elongation Variation) |
- |
1588 |
|
- |
| 3.2(Requirements(Cl. 4 Table
1 of IS: 8783 (part 2) After Ageing Elongation Test) |
- |
1588 |
|
- |
| 3.2(Requirements(Cl. 4 Table
1 of IS: 8783 (part 2) Tensile strength Variation) |
- |
1588 |
|
- |
| 3.2(Requirements(Cl. 4 Table
1 of IS: 8783 (part 2) After Ageing Tensile strength) |
- |
1588 |
|
- |
| 3.2(Requirements(Cl. 4 Table
1 of IS: 8783 (part 2) Befor Ageing Elongation Test) |
- |
400 |
|
- |
| 3.2(Requirements(Cl. 4 Table
1 of IS: 8783 (part 2) Befor Ageing Tensile strength) |
- |
400 |
|
- |
| 3.2(Requirements(Cl. 4 Table
1 of IS: 8783 (part 2) Volume resistivity@ 85 °C) |
- |
600 |
|
- |
| 3.2(Requirements(Cl. 4 Table
1 of IS: 8783 (part 2) Volume resistivity@Room Temprature ) |
- |
600 |
|
- |
| 3.1(Resistance Test ((Cl 6 of
IS:8783(Part I):95
) |
- |
700 |
|
- |
| 3.1(Annealing Test(Cl. 6
of IS:8783(Part I):95
) |
- |
1858 |
|
- |
|
30 Nov, 2028 |
- - |
| 67 |
IS 14255 (1995) |
Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification |
- |
57150 View breakup
Rs. 57,150/- (for type test);
Multicore cables: additional charges Rs. 500/- per core per test.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1 a) i)(Tests on phase/street light conductor: tensile test - Test method IS10810:Part 2) |
- |
900 |
|
- |
| 10.1 a) ii)(Wrapping test - 10810: Part 3) |
- |
500 |
|
- |
| 10.1 a) iii)(Resistance test - IS10810: Part 5) |
- |
1300 |
|
- |
| 10.1 b) i)(Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
8000 |
|
- |
| 10.1 b) ii)(Test on messenger conductor: Elongation test - Cl 11.3) |
- |
800 |
|
- |
| 10.1 b) iii)(Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
1300 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
1000 |
|
- |
| 10.1 c) i)(Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
1000 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
4150 |
|
- |
| 10.1 c) ii)(Ageing in air oven : Elongation variation- IS 10810: Part 11) |
- |
4150 |
|
- |
| 10.1 c) iii)(Hot set test: Elongation under load - IS 10810: Part 30) |
- |
625 |
|
- |
| 10.1 c) iii)(Hot set test: Permanent elongation (set) after cooling - IS 10810: Part 30) |
- |
625 |
|
- |
| 10.1 c) iv)(Shrinkage test : Shrinkage - 10810:Part 12) |
- |
650 |
|
- |
| 10.1 c) iv)(Shrinkage test : Crack Observed - 10810:Part 12) |
- |
650 |
|
- |
| 10.1 c) v)(Water ahsorption (Gravimetric) - IS 10810: Part 33 ) |
- |
10000 |
|
- |
| 10.1 d) i)(Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
1000 |
|
- |
| 10.1 d) i)(Physical test for PE insulation: elongation at break - IS 10810: Part 7) |
- |
1000 |
|
- |
| 10.1 d) ii)(Melt flow index- IS 10810: Part 23) |
- |
2150 |
|
- |
| 10.1 d) iv)(Vicat softening point -IS 10810: Part 22) |
- |
2150 |
|
- |
| 10.1 d) v)(Environmental stress cracking -IS 10810:Part29) |
- |
1700 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
1350 |
|
- |
| 10.1 f)(Insulation resistance (Volume resistivity) test b) volume resistivity at 70°C - IS 10810: Part 43) |
- |
1350 |
|
- |
| 10.1 g)(High voltage test - IS10810:Part 45) |
- |
1550 |
|
- |
| 11.4(Bending Test on the Completed Cable ( Optional) ) |
- |
2300 |
|
- |
| 7.2( Thickness of insulation) |
- |
1550 |
|
- |
|
30 Nov, 2028 |
- - |
| 68 |
IS 9335 : Part 3 : Sec 5 (1985) |
Specification for cellulosic papers for electrical purposes: Part 3 specifications for individual materials: Sec 5 special papers |
All |
41883 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5, Table 5 to 8(Thickness) |
- |
575 |
|
- |
| 5, Table 5 to 8(Substance) |
- |
1150 |
|
- |
| 5, Table 5 to 8(Apparent density) |
- |
1725 |
|
- |
| 5, Table 5 to 8(Tensile strength) |
- |
1725 |
|
- |
| 5, Table 5 to 8(elongation) |
- |
0 |
|
Test Charges included in Tensile Strength test. |
| 5, Table 5 to 8(Internal tearing resistance) |
- |
1725 |
|
- |
| 5, Table 5 to 8(Bursting strength) |
- |
1150 |
|
- |
| 5, Table 5 to 8(Moisture Content) |
- |
1150 |
|
- |
| 5, Table 5 to 8(Ash) |
- |
1725 |
|
- |
| 5, Table 5 to 8(Conductivity of Aqueous Extract) |
- |
1725 |
|
- |
| 5, Table 5 to 8(pH of Aqueous Extract) |
- |
1725 |
|
- |
| 5, Table 5 to 8(Air permeability) |
- |
1150 |
|
- |
| 5, Table 5 to 8(Water absorption) |
- |
920 |
|
- |
| 5, Table 5 to 8(Electric strength) |
- |
1150 |
|
- |
| 5, Table 5 to 8(Dissipation factor of dry un impregnated paper) |
- |
2875 |
|
- |
| 5, Table 5 to 8(Heat Stability) |
- |
21413 |
|
- |
| 5, Table 5 to 8(Thickness) |
- |
575 |
|
- |
| 5, Table 5 to 8(Substance) |
- |
1150 |
|
- |
| 5, Table 5 to 8(Apparent density) |
- |
1725 |
|
- |
| 5, Table 5 to 8(Tensile strength) |
- |
1725 |
|
- |
| 5, Table 5 to 8(elongation) |
- |
0 |
|
Test Charges included in Tensile Strength test. |
| 5, Table 5 to 8(Internal tearing resistance) |
- |
1725 |
|
- |
| 5, Table 5 to 8(Bursting strength) |
- |
1150 |
|
- |
| 5, Table 5 to 8(Moisture Content) |
- |
1150 |
|
- |
| 5, Table 5 to 8(Ash) |
- |
1725 |
|
- |
| 5, Table 5 to 8(Conductivity of Aqueous Extract) |
- |
1725 |
|
- |
| 5, Table 5 to 8(pH of Aqueous Extract) |
- |
1725 |
|
- |
| 5, Table 5 to 8(Air permeability) |
- |
1150 |
|
- |
| 5, Table 5 to 8(Water absorption) |
- |
920 |
|
- |
| 5, Table 5 to 8(Electric strength) |
- |
1150 |
|
- |
| 5, Table 5 to 8(Dissipation factor of dry un impregnated paper) |
- |
2875 |
|
- |
| 5, Table 5 to 8(Heat Stability) |
- |
21413 |
|
- |
|
30 Nov, 2028 |
- - |
| 69 |
IS 13730 : Part 9 (1994) |
Specification for particular types of winding wires: Part 9 polyester enamelled round aluminium wire, class 138 |
- |
831950 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause No. 4(Dimensions) |
- |
500 |
|
- |
| Clause No. 5(Electrical resistance) |
- |
600 |
|
- |
| Clause No. 6(Elongation %) |
- |
600 |
|
- |
| Clause No. 8(Flexibility and adherence (i) Mandrel winding test) |
- |
225 |
|
- |
| Clause No. 8(Flexibility and adherence (ii) Stretching test) |
- |
225 |
|
- |
| Clause No. 8(Flexibility and adherence (iii) Jerk test) |
- |
225 |
|
- |
| Clause No. 8(Flexibility and adherence (iv) Peel test) |
- |
225 |
|
- |
| Clause No. 9(Heat Shock test) |
- |
800 |
|
- |
| Clause No. 10(Cut through test) |
- |
850 |
|
- |
| Clause No. 11(Resistance to Abrasion test) |
- |
850 |
|
- |
| Clause No. 12(Resistance to solvent test) |
- |
850 |
|
- |
| Clause No. 13(Breakdown voltage test) |
- |
1800 |
|
- |
| Clause No. 15(Temperature index test) |
- |
821600 |
|
- |
|
30 Nov, 2028 |
- - |
| 70 |
IS 13730 : Part 16 (1996) |
Specifications for particular types of winding wires: Part 16 polyester enamelled rectangular copper wire class 155 |
- |
830500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause No. 4(Dimensions) |
- |
500 |
|
- |
| Clause No. 5(Electrical resistance) |
- |
600 |
|
- |
| Clause No. 6(Elongation %) |
- |
600 |
|
- |
| Clause No. 7() |
- |
500 |
|
- |
| Clause No. 8(Flexibility and adherence (i) Mandrel winding test) |
- |
225 |
|
- |
| Clause No. 8(Flexibility and adherence (ii) Stretching test) |
- |
225 |
|
- |
| Clause No. 8(Flexibility and adherence (iii) Jerk test) |
- |
225 |
|
- |
| Clause No. 8(Flexibility and adherence (iv) Peel test) |
- |
225 |
|
- |
| Clause No. 9(Heat Shock test) |
- |
800 |
|
- |
| Clause No. 12(Resistance to solvent test) |
- |
850 |
|
- |
| Clause No. 13(Breakdown voltage test) |
- |
1800 |
|
- |
| Clause No. 15(Temperature index test) |
- |
821600 |
|
- |
|
30 Nov, 2028 |
- - |
| 71 |
IS 13730 : Part 32 (2018) |
Specifications for particular types of winding wires: Part 32 glass fibre wound, resin or varnish impregnated, bare or enamelled rectangular copper wire, temperature index 155 (First Revision) |
- |
828600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause No. 4(Dimensions) |
- |
500 |
|
- |
| Clause No. 5(Electrical resistance) |
- |
600 |
|
- |
| Clause No. 6(Elongation %) |
- |
600 |
|
- |
| Clause No. 7(Springiness) |
- |
500 |
|
- |
| Clause No. 8(Flexibility and adherence (i) Mandrel winding test) |
- |
225 |
|
- |
| Clause No. 8(Flexibility and adherence (ii) Stretching test) |
- |
225 |
|
- |
| Clause No. 8(Flexibility and adherence (iii) Jerk test) |
- |
225 |
|
- |
| Clause No. 8(Flexibility and adherence (iv) Peel test) |
- |
225 |
|
- |
| Clause No. 13(Breakdown voltage test) |
- |
1800 |
|
- |
| Clause No. 15(Temperature index test) |
- |
821600 |
|
- |
|
30 Nov, 2028 |
- - |
| 72 |
IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
- |
125450 View breakup
Rs. 1,25,450/- (for type test) ;
Multicore cables: additional charges Rs. 500/- per core per test.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.1(MATERIALS : CONDUCTOR) |
- |
1550 |
|
- |
| 15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
600 |
|
- |
| 15.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
600 |
|
- |
| 15.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
600 |
|
- |
| 15.1 a) 3)(Tests on conductor : Wrapping test ( for aluminium )) |
- |
500 |
|
- |
| 15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
700 |
|
- |
| 15.1 d)1)(Phyaical tests for insulation : Tensile Test) |
- |
450 |
|
- |
| 15.1 d)1)(Phyaical tests for insulation : Elongation ) |
- |
450 |
|
- |
| 15.1 d)1)(Physical tests for sheath : Tensile stregth ) |
- |
450 |
|
- |
| 15.1 d)1)(Physical tests for sheath : Elongation ) |
- |
450 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
1750 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
1750 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1750 |
|
- |
| 15.1 d)2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1750 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1750 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1750 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1750 |
|
- |
| 15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
1750 |
|
- |
| 15.1 d)3)(Phyaical tests for insulation : Shrinkage ) |
- |
1300 |
|
- |
| 15.1 d)3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
0 |
|
- |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage ) |
- |
1300 |
|
- |
| 15.1 d)3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
0 |
|
- |
| 15.1 d)4)(Hot deformation : Insulation ) |
- |
1450 |
|
- |
| 15.1 d)4)(Hot deformation : Sheath ) |
- |
1450 |
|
- |
| 15.1 d)5)( Loss of mass in air oven- Insulation ) |
- |
7000 |
|
- |
| 15.1 d)5)( Loss of mass in air oven- sheath ) |
- |
7000 |
|
- |
| 15.1 d)6)(Heat shock test- Insulation ) |
- |
900 |
|
- |
| 15.1 d)6)(Heat shock test- sheath ) |
- |
900 |
|
- |
| 15.1 d)7)(Thermal stability- insulation ) |
- |
1500 |
|
- |
| 15.1 d)7)(Thermal stability- Sheath ) |
- |
1500 |
|
- |
| 15.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
600 |
|
- |
| 15.1 e)(Insulation resistance test : IR Constant ) |
- |
600 |
|
- |
| 15.1 f)(High voltage test ( water immersion test )) |
- |
9500 |
|
- |
| 15.1 g)(High voltage test at room temperature) |
- |
1000 |
|
- |
| 15.4 a)(Cold bend test- Insulation ( Optional test)) |
- |
3000 |
|
- |
| 15.4 a)(Cold bend test- Sheath ( Optional test)) |
- |
3000 |
|
- |
| 15.4 b)(Cold impact test- Insulation ( Optional test)) |
- |
3000 |
|
- |
| 15.4 b)(Cold impact test- Sheath ( Optional test)) |
- |
3000 |
|
- |
| 16.1(DETAILS OF TESTS : General) |
- |
0 |
|
- |
| 16.4(Flammability Test) |
- |
1500 |
|
- |
| 16.5(Oxygen Index Test) |
- |
3500 |
|
- |
| 16.6(Flame Retardance Test on Single Cables) |
- |
6500 |
|
- |
| 16.7(Flame Retardance Test on Bunched Cables) |
- |
9200 |
|
- |
| 16.9(Test for Halogen Acid Gas Evolution) |
- |
4500 |
|
- |
| 16.1(Temperature Index) |
- |
5500 |
|
- |
| 12.3.1(INNER SHEATH :Thickness of Inner Sheath) |
- |
0 |
|
- |
| 9.2(INSULATION : Thickness of Insulation) |
- |
1300 |
|
- |
| 14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
1300 |
|
- |
| 14.4.2(Thickness of Outer Sheath : Armoured Cables) |
- |
1300 |
|
- |
| 13.3(Armouring : Dimensions -Wire Diameter) |
- |
714.28 |
|
- |
| 13.3(Armouring : Dimensions -Formed wire ) |
- |
714.28 |
|
- |
| 13.6 a)(ARMOURING: Tensile Strength) |
- |
714.28 |
|
- |
| 13.6 b)(ARMOURING: Elongation ) |
- |
714.28 |
|
- |
| 13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
714.28 |
|
- |
| 13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
714.28 |
|
- |
| 13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
714.28 |
|
- |
| 13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
714.28 |
|
- |
| 13.6 g)(ARMOURING: Resistivity) |
- |
714.28 |
|
- |
|
30 Nov, 2028 |
- - |
| 73 |
IS 4770 (1991) |
Rubber gloves - Electrical purposes - Specification (First Revision) |
- |
25650 View breakup
Rs. 25,650/- (for type test)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1.1.a(Thickness test) |
- |
1450 |
|
NA |
| 6.1.1.b(Tensile test) |
- |
800 |
|
NA |
| 6.1.1.c(Elongation at break %) |
- |
800 |
|
NA |
| 6.1.1.d(Tension set) |
- |
800 |
|
NA |
| 6.1.1.e(Tensile strength at 200 % elongation) |
- |
800 |
|
NA |
| 6.1.1.f(Tear Strength) |
- |
800 |
|
NA |
| 6.1.1.g(Change in tensile and elongation strength after heat ageing) |
- |
8400 |
|
NA |
| 6.1.1 j(Puncture resistance test) |
- |
800 |
|
NA |
| 6.1.1. k(Moisture absorption test) |
- |
2000 |
|
NA |
| 6.1.1.n(Proof voltage and leakage current) |
- |
1300 |
|
NA |
| 6.1.1.p(Breakdown voltage test) |
- |
2050 |
|
NA |
| 6.1.1.p(Breakdown voltage test) |
- |
0 |
|
nA |
| 6.1.1.q(Annex H) |
- |
2050 |
|
NA |
|
30 Nov, 2028 |
- Exclude Cl. No. 6.1.1 k Nitrogen content (For natural rubber only) and Cl. No. 6.1.1 m Ash Content (For natural Rubber only). |
| 74 |
IS 13573 : Part 1 (2011) |
Cable accessories for extruded power cables - Specification: Part 1 for working voltages from 1.1 kV up to and including 3.3 kV(E) - Test methods and test requirements (First Revision) |
- |
350013 View breakup
For joints - Rs. 3,50,013/- ;
For stop ends - Rs. 53,400/- ;
For outdoor terminations - Rs. 2,24,400/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Table (3), Table (4)& Table (5)(Examination ) |
- |
500 |
|
NA |
| Table (3), Table (4)& Table (5)(Insulation resistance test ) |
- |
2800 |
|
NA |
| Table (3), Table (4)& Table (5)(ac voltage withstand in water) |
- |
1000 |
|
NA |
| Table (3), Table (4)& Table (5)(ac voltage withstand in air ) |
- |
1000 |
|
NA |
| Table (3), Table (4)& Table (5)(Impulse voltage test at ambient temperature) |
- |
27300 |
|
NA |
| Table (3) & Table (5)(Heating cycle in water ) |
- |
94500 |
|
NA |
| Table (3) & Table (5)(Heating cycle in air ) |
- |
94500 |
|
NA |
| Table (3) & Table (4)(Impact test ) |
- |
16000 |
|
NA |
| Table 3 xii(Screen short circuit) |
- |
112413 |
|
Up to 50 kA for 1 sec : Rs. 68770
Up to 31.5 kA for 3 sec : Rs. 112413 |
|
30 Nov, 2028 |
- - |
| 75 |
IS 14697 (2021) |
ac STATIC TRANSFORMER OPERATED WATTHOUR METERS CLASS 02 S AND 05 S AND VAR-HOUR METERS CLASS 02 S 05 S AND 10 S - SPECIFICATION First Revision |
CLASS 0.2 S 0.5 S AND 1.0 S |
147297 View breakup
Rs. 1,47,297/- (For all tests including general & construction).
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(General) |
- |
0 |
|
- |
| 6.2(Meter Case) |
- |
0 |
|
- |
| 6.3(Window) |
- |
0 |
|
- |
| 6.4(Terminals, Terminals Block(s) and Protective Earth Terminal) |
- |
0 |
|
- |
| 6.5(Terminal Cover(s)) |
- |
0 |
|
- |
| 6.6(Clearance and Creepage Distance) |
- |
0 |
|
- |
| 6.7(Insulating Encased Meter) |
- |
0 |
|
- |
| 6.10(Display of measured values) |
- |
0 |
|
- |
| 6.11(Output device) |
- |
0 |
|
- |
| 9.5, 12.7.6.2(Impulse voltage test) |
- |
0 |
|
- |
| 12.7.6.3, 9.5(ac Voltage test) |
- |
0 |
|
- |
| 12.7.6.4(Insulation resistance test) |
- |
0 |
|
- |
| 11.1(Limits of Error Due to Variation of the Current) |
- |
0 |
|
- |
| 12.15(Interpretation of Test Results) |
- |
0 |
|
- |
| 12.14, 11.6(Test of Meter Constant/Registration) |
- |
0 |
|
- |
| 12.13 & 11.5(Starting Current) |
- |
0 |
|
- |
| 12.12, 11.4(Test of No-Load Condition) |
- |
0 |
|
- |
| 12.11, 11.3(Test of Ambient Temperature Influence) |
- |
0 |
|
- |
| 12.16, 11.7(Repeatability of Error Test) |
- |
0 |
|
- |
| 11.2, 12.10(Limits of error due to other Influence Quantities) |
- |
0 |
|
- |
| 11.2(Voltage variation) |
- |
0 |
|
- |
| 11.2(Frequency variation) |
- |
0 |
|
- |
| 11.2(Wave form: 10 percent of third harmonic in the current) |
- |
0 |
|
- |
| 11.2(Reversed phase sequence) |
- |
0 |
|
- |
| 11.2(Voltage unbalance) |
- |
0 |
|
- |
| 11.2(Auxiliary voltage ± 15 percent) |
- |
0 |
|
- |
| 11.2("Phase of Auxiliary supply
voltage by 120 degree") |
- |
0 |
|
- |
| 11.2(Continuous magnetic induction of external origin) |
- |
0 |
|
- |
| 11.2(Magnetic induction of external origin 0.5 mT) |
- |
0 |
|
- |
| 11.2(‘Abnormal’ ac magnetic induction of external origin 10 mT) |
- |
0 |
|
- |
| 12.7.1, 9.1(Test of Power Consumption) |
- |
0 |
|
- |
| 12.7.2, 9.2.2(Test of Influence of Supply Voltage) |
- |
0 |
|
- |
| 9.2.3 12.7.3(Test of Influence of Short-time Overcurrents) |
- |
0 |
|
- |
| 12.7.4, 9.3(Test of Influence of Self-Heating) |
- |
0 |
|
- |
| 12.7.5, 9.4(Test of Influence of Heating) |
- |
0 |
|
- |
| 12.17, 9.6(Test of Immunity to Earth/Phase Fault) |
- |
0 |
|
- |
| 12.8.6, 10.2(Radio Interference Measurement) |
- |
0 |
|
- |
| 12.8.4, 10.1(Fast Transient Burst Test) |
- |
0 |
|
- |
| 12.8.2, 10.1(Test for Immunity to Electrostatic Discharge (ESD)) |
- |
0 |
|
- |
| 12.8.3, 10.1(Test for immunity to electromagnetic HF field) |
- |
0 |
|
- |
| 12.8.5, 10.1(Surge Immunity test) |
- |
0 |
|
- |
| 12.6.1(Dry heat test) |
- |
0 |
|
- |
| 12.6.2(Cold Test) |
- |
0 |
|
- |
| 12.6.3(Damp Heat Cycle Test) |
- |
0 |
|
- |
| 12.3.2(Vibration test) |
- |
0 |
|
- |
| 12.3.1(Shock test) |
- |
0 |
|
- |
| 12.3.3(Spring hammer test) |
- |
0 |
|
- |
| 12.5, 6.9(Test of Protection Against Penetration of Dust and Water) |
- |
0 |
|
- |
| 12.4(Test of resistance to heat and fire) |
- |
0 |
|
- |
| 7.1 a)(MARKING OF METERS : Name Plate) |
- |
0 |
|
- |
| 7.1 b)(MARKING OF METERS : Name Plate) |
- |
0 |
|
- |
| 7.1 c)(MARKING OF METERS : Name Plate) |
- |
0 |
|
- |
| 7.1 d)(MARKING OF METERS : Name Plate) |
- |
0 |
|
- |
| 7.1 e)(MARKING OF METERS : Name Plate) |
- |
0 |
|
- |
| 7.1 f)(MARKING OF METERS : Name Plate) |
- |
0 |
|
- |
| 7.1 g)(MARKING OF METERS : Name Plate) |
- |
0 |
|
- |
| 7.1 h)(MARKING OF METERS : Name Plate) |
- |
0 |
|
- |
| 7.1 j)(MARKING OF METERS : Name Plate) |
- |
0 |
|
- |
| 7.1 k)(MARKING OF METERS : Name Plate) |
- |
0 |
|
- |
| 7.1 m)(MARKING OF METERS : Name Plate) |
- |
0 |
|
- |
| 7.1 n)(MARKING OF METERS : Name Plate) |
- |
0 |
|
- |
| 7.1 p)(MARKING OF METERS : Name Plate) |
- |
0 |
|
- |
| 7.1(MARKING OF METERS : Name Plate) |
- |
0 |
|
- |
| 7.1.1(BIS certification Marking) |
- |
0 |
|
- |
| 7.2(Connection diagrams and terminal marking) |
- |
0 |
|
- |
|
30 Nov, 2028 |
- - |
| 76 |
IS/IEC 60079 : PART 31 (2013) |
Explosive atmospheres: Part 31 equipment dust ignition protection by enclosure "T" (First Revision) |
- |
121148 View breakup
Rs. 13,500/- (for routine test only) ;
Rs.1,21,148/-(for product wise applicable tests)
Documentation charges will be Rs. 6,000/- Extra.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Observation) |
- |
0 |
|
NA |
| 4.2(Observation) |
- |
6000 |
|
NA |
| 4.3(Observation) |
- |
24200 |
|
NA |
| 4.4(Observation) |
- |
12200 |
|
NA |
| 5(Observation) |
- |
22400 |
|
NA |
| 6.1.1.1(Thermal Endurance to heat, Thermal Endurance to Cold & Impact Test) |
- |
50300 |
|
NA |
| 6.1.1.2(Impact test) |
- |
2000 |
|
NA |
| 6.1.1.3(Pressure test) |
- |
4500 |
|
NA |
| 6.1.1.4(Ingress Protection test) |
- |
7848 |
|
NA |
| 6.1.4(Temperature) |
- |
7700 |
|
NA |
| 7(Observation) |
- |
2000 |
|
NA |
| 6.1.2(Temperature) |
- |
0 |
|
NA |
|
30 Nov, 2028 |
- - |
| 77 |
IS 369 (2019) |
Household electric direct - Acting room heaters - Performance requirements (Fourth Revision) |
Up to and including 5 kW |
20350 View breakup
Rs. 18925/- up to including 1 kW,
Rs. 20,350/- above 1 kW
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 302-2-30:2007(Classification) |
- |
0 |
|
--- |
| Cl.18 of IS 302-2-30:2007 (Endurance) |
- |
0 |
|
--- |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
350 |
|
Total Test charge for cl. no. 7 is Rs. 350/- |
| Cl.8 of IS 302-2-30:2007 &IS:302-1:2008(Protection Against Access to Live Parts) |
- |
350 |
|
Total Test charge for cl. no. 8 is Rs. 350/- |
| Cl.10 of IS 302-2-30:2007 &IS:302-1:2008(Power Input and Current) |
- |
350 |
|
Total Test charge for cl. no. 10 is Rs. 350/- |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
500 |
|
Total Test charge for cl. no. 11 is Rs. 500/- |
| Cl.13 of IS 302-2-30:2007 &IS:302-1:2008(Leakage Current & Electric Strength at operating temp) |
- |
350 |
|
Total Test charge for cl. no. 13 is Rs. 350/- |
| Cl.14 of IS 302-2-30:2007 &IS:302-1:2008(Transient Over Voltages) |
- |
2250 |
|
Total Test charge for cl. no. 14 is Rs. 2250/- |
| Cl.15 of IS 302-2-30:2007 &IS:302-1:2008(Moisture Resistance) |
- |
2250 |
|
Total Test charge for cl. no. 15 is Rs. 2250/- |
| Cl.19 of IS 302-2-30:2007 &IS:302-1:2008(Abnormal Operation) |
- |
2125 |
|
up to including 1 Kw : Rs. 700/-
above 1 Kw : Rs. 2125/- |
| Cl.20 of IS 302-2-30:2007 &IS:302-1:2008(Stability & Mechanical Hazards) |
- |
350 |
|
Total Test charge for cl. no. 20 is Rs. 350/- |
| Cl.21 of IS 302-2-30:2007 &IS:302-1:2008(Mechanical Strength) |
- |
500 |
|
Total Test charge for cl. no. 21 is Rs. 500/- |
| Cl.22 of IS 302-2-30:2007 &IS:302-1:2008(Construction) |
- |
1100 |
|
Total Test charge for cl. no. 22 is Rs. 1100/- |
| Cl.23 of IS 302-2-30:2007 &IS:302-1:2008(Internal Wiring) |
- |
350 |
|
Total Test charge for cl. no. 23 is Rs. 350/- |
| Cl.24 of IS 302-2-30:2007 &IS:302-1:2008(Component) |
- |
350 |
|
Total Test charge for cl. no. 24 is Rs. 350/- |
| Cl.25 of IS 302-2-30:2007 &IS:302-1:2008(Supply Connection and External Flexible Cords ) |
- |
700 |
|
Total Test charge for cl. no. 25 is Rs. 700/- |
| Cl.26 of IS 302-2-30:2007 &IS:302-1:2008(Terminal for External Conductors) |
- |
350 |
|
Total Test charge for cl. no. 26 is Rs. 350/- |
| Cl.27 of IS 302-2-30:2007 &IS:302-1:2008(Provision for Earthing) |
- |
350 |
|
Total Test charge for cl. no. 27 is Rs. 350/- |
| Cl.28 of IS 302-2-30:2007 &IS:302-1:2008(Screws and Connections) |
- |
350 |
|
Total Test charge for cl. no. 28 is Rs. 350/- |
| Cl.29 of IS 302-2-30:2007 &IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation.) |
- |
350 |
|
Total Test charge for cl. no. 29 is Rs. 350/- |
| Cl.30 of IS 302-2-30:2007 &IS:302-1:2008(Resistance to Heat and Fire.) |
- |
2025 |
|
Total Test charge for cl. no. 30 is Rs. 2025/- |
| Cl.31 of IS 302-2-30:2007 &IS:302-1:2008(Resistance to Rusting) |
- |
350 |
|
Total Test charge for cl. no. 31 is Rs. 350/- |
| Cl.7 of IS 369:2019(Dimensions) |
- |
500 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| Cl.8 of IS 369:2019(Temperature rises of air-outlet grilles and external surfaces) |
- |
750 |
|
Total Test charge for cl. no. 8 is Rs. 750/- |
| Cl.9 of IS 369:2019(Temperature rises of surfaces surrounding the heater) |
- |
750 |
|
Total Test charge for cl. no. 9 is Rs. 750/- |
| Cl.10 of IS 369:2019(Warming-up time of the heater) |
- |
650 |
|
Total Test charge for cl. no. 10 is Rs. 650/- |
| Cl.14 of IS 369:2019(Inrush current) |
- |
500 |
|
Total Test charge for cl. no. 14 is Rs. 500/- |
| Cl.15 of IS 369:2019(Effect of radiant heat) |
- |
700 |
|
Total Test charge for cl. no. 15 is Rs. 700/- |
| Cl.16 of IS 369:2019(Usable power) |
- |
500 |
|
Total Test charge for cl. no. 15 is Rs. 500/- |
| Cl.16 of IS 302-2-30:2007 &IS:302-1:2008(Leakage Current & Electric Strength ) |
- |
350 |
|
Total Test charge for cl. no. 16 is Rs. 350/- |
|
30 Nov, 2028 |
- Exclude Cl. No. 11 Stability of room temperature, Cl.12 Set-back, Cl. 13 Frost protection temperature, Cl. No. 19.11.4.7 as per IS 302-2-30 Abnormal Operation. |
| 78 |
IS 13779 (2020) |
ac STATIC WATTHOUR METERS CLASS 1 AND 2-Specefication |
Class 1& 2 |
138390 View breakup
Rs. 1,38,390/- (For all tests including general & construction - For Imax upto 200 A, 1 Phase & 3 Phase).
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 12.7.6.2(Impulse voltage test) |
- |
0 |
|
- |
| 6.1(General) |
- |
0 |
|
- |
| 6.2(Meter Case) |
- |
0 |
|
- |
| 6.3(Window) |
- |
0 |
|
- |
| 6.4(Terminals, terminal block and protective earth terminal) |
- |
0 |
|
- |
| 6.5(Terminals covers and Extended Terminal Cover) |
- |
0 |
|
- |
| 6.6(Clearance and creepage distances) |
- |
0 |
|
- |
| 6.4(Terminals, terminals block(s) and protective earth terminal) |
- |
0 |
|
- |
| 6.7(Insulating encased meter) |
- |
0 |
|
- |
| 7.1(Name Plate) |
- |
0 |
|
- |
| 7.2(Connection diagrams and terminal marking) |
- |
0 |
|
- |
| 6.10(Display of measured values) |
- |
0 |
|
- |
| 6.11(Output device) |
- |
0 |
|
- |
| 12.7.6.3(ac high voltage test) |
- |
0 |
|
- |
| 12.7.6.4(Insulation resistance test) |
- |
0 |
|
- |
| 11.1(Test on limits of error due to variation of current) |
- |
0 |
|
- |
| 12.16(Limits of Error and Interpretation or Test Results) |
- |
0 |
|
- |
| 12.15 & 11.6(Test of meter constant) |
- |
0 |
|
- |
| 12.14 & 11.5(Test of starting condition) |
- |
0 |
|
- |
| 12.13 & 11.4(Test of no-load condition) |
- |
0 |
|
- |
| 12.12 & 11.3(Test of ambient temperature influence) |
- |
0 |
|
- |
| 12.17, 11.7(Repeatability of Error Test) |
- |
0 |
|
- |
| 12.11, 11.2(Test of Influence Quantities) |
- |
0 |
|
- |
| 12.7.1(Test of power consumption) |
- |
0 |
|
- |
| 12.7.2(Test of influence of supply voltage) |
- |
0 |
|
- |
| 12.7.3(Test of influence of short time over currents) |
- |
0 |
|
- |
| 12.7.4(Test of Influence of self heating) |
- |
0 |
|
- |
| 12.7.5(Test of influence of heating) |
- |
0 |
|
- |
| 12.8(Test of immunity to earth/phase fault) |
- |
0 |
|
- |
| 12.9.6, 10.2(Radio Interference Measurement) |
- |
0 |
|
- |
| 10.1, 12.9.2(Test for Immunity to Electrostatic Discharge (ESD)) |
- |
0 |
|
- |
| 10.1, 12.9.4(Fast Transient Burst Test) |
- |
0 |
|
- |
| 10.1, 12.9.3(Test for immunity to electromagnetic HF field) |
- |
0 |
|
- |
| 12.9.5(Surge Immunity Test) |
- |
0 |
|
- |
| 12.6.1(Dry heat test) |
- |
0 |
|
- |
| 12.6.2(Cold test) |
- |
0 |
|
- |
| 12.6.3(Damp heat cyclic test) |
- |
0 |
|
- |
| 12.3.2(Vibration test) |
- |
0 |
|
- |
| 12.3.1(Shock test) |
- |
0 |
|
- |
| 12.5(Test of protection against penetration of dust and water) |
- |
0 |
|
- |
| 12.4(Test of resistance to heat and fire) |
- |
0 |
|
- |
| 12.3.3(Spring hammer test) |
- |
0 |
|
- |
|
30 Nov, 2028 |
- - |
| 79 |
IS 648 (2006) |
Cold rolled non-oriented electrical steel sheet and strip - Fully processed type - Specification (Fifth Revision) |
All Grades as per IS |
36535 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 8.1(Thickness) |
- |
575 |
|
Lamination Thickness test for CRNO strips |
| Cl. No. 6.3.2(Observation) |
- |
575 |
|
Adherence test for CRNO strips |
| Cl. No. 7.1.1.1 & Table-1(Polarization in Tesla) |
- |
4695 |
|
AC Magnetization for CRNO Strips At 2500, 5000 & 10000 AT/m |
| Cl. No. 7.1.2.1 , 7.1.2.2 & Table-1(Loss in W/kg) |
- |
11290 |
|
Specific Core Loss Measurement (1.0 Tesla & 1.5 Tesla) with Annealing & with Ageing for CRNO strips |
| Cl. No. 7.1.2.1 & Table-1(Loss in W/kg) |
- |
9620 |
|
Specific Core Loss Measurement (1.0 Tesla & 1.5 Tesla) without Annealing & with Ageing for CRNO strips |
| Cl. No. 7.1.2.1 & Table-1(Loss in W/kg) |
- |
2030 |
|
Specific Core Loss Measurement (1.0 Tesla & 1.5 Tesla) without Annealing & without Ageing for CRNO strips |
| Cl. No. 7.1.2.4.1 & Table-1(Loss in %) |
- |
2185 |
|
Anisotropy of Losses for CRNO Strips |
| Cl. No. 7.2.6(SIR in Ω-cm2/lamination) |
- |
2230 |
|
Surface Insulation Resistivity for CRNO Strips |
| Cl. No. 7.2.7(T.E. in Ω-cm2/lamination) |
- |
11385 |
|
Thermal Effect on Coating for CRNO Strips |
| Cl. No. 9.1 &Table-4(SF in %) |
- |
575 |
|
Stacking Factor for CRNO Strips |
| Cl. No. 9.2 & Table-1(Bends) |
- |
575 |
|
Ductility (Bend test) for CRNO Strips |
| Cl. No. 7.2.8(Insulation Check) |
- |
2450 |
|
Resistance to Solvent for CRNO Strips |
|
30 Nov, 2028 |
- Exclusion: Cl 8.2 (Width), Cl 8.3 (Length) , Cl 8.5 (Shape), Cl 8.6 (Flatness) |
| 80 |
IS 3024 (2015) |
Grain oriented electrical steel sheet and strip (Third Revision) |
All Grades as per IS |
27735 View breakup
Rs. 27,735/- (for all grades)
Rs. 16,235/- for CG, HP & domain refined (which withstand annealing) grades (Epstein method)
Rs. 23,045/- For domain refined grades which does not withstand annealing (SST method)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 11.1(Thickness) |
- |
575 |
|
1. 16235/-
for CG, HP & domain refined (which withstand annealing) grades (Epstein method)
2. 23045/-
For domain refined grades which does not withstand annealing (SST method) |
| Cl. No. 8.1 & Table-1 or Table-2(Loss in W/kg) |
- |
3125 |
|
Specific Core Loss Measurement for CRGO strips with Annealing |
| Cl. No. 8.2 & Table-1 or Table-2(Polarization in Tesla) |
- |
1565 |
|
Magnetic Polarization for CRGO Strips |
| Cl. No. 9.0 & Table-3(SIR in Ω-cm2/lamination) |
- |
2230 |
|
Surface Insulation Resistivity for CRGO Strips |
| Cl. No. 10.1 & Table-4(SF in %) |
- |
575 |
|
Stacking Factor for CRGO Strips |
| Cl. No. 10.2.2(Bends) |
- |
575 |
|
Ductility (Bend test) for CRGO Strips |
| Cl. No. 14.5 & Table-1 or Table-2(Loss in W/kg) |
- |
5750 |
|
Specific Core Loss Measurement for CRGO Sheet |
| Cl. No. 14.5 & Table-1 or Table-2(Polarization in Tesla) |
- |
5750 |
|
Magnetic Polarization for CRGO Sheet |
| Cl. No. 14.6(Loss in W/kg) |
- |
7590 |
|
Specific Core Loss Measurement After Accelerated Ageing Test
for CRGO Sheet / CRGO Strips |
| Cl. No. 8.1 & Table-1 or Table-2(Loss in W/kg) |
- |
1455 |
|
Specific Core Loss Measurement for CRGO strips
Without Annealing |
|
30 Nov, 2028 |
- Exclusion: Cl 7.4 (Surface Condition), Cl 11.2 (Width), Cl 11.3 (Length), Cl 11.4 (Edge Camber), Cl 11.5 (Flatness), Cl 11.6 (Burr Height), Cl 12 (Workmanship, Finish and Appearance), Cl. No. 11.7 (Residual Curvature) |
| 81 |
IS/IEC 60947 : Part 4 : Sec 1 (2012) |
Low - Voltage switchgear and controlgear: Part 4 contactors and motor - Starters: Sec 1 electromechanical contactors and motor - Starters (First Revision) |
- |
455661 View breakup
Rs. 4,55,661/- (For complete testing)
One rating : Seq I Rs. 57,128/- ;
Seq II Rs. 80,500/- ; Seq III Rs. 60,800/- ; Seq IV : Rs. 9,200/- ; Seq V Rs. 8,286/- ; Routine test Rs. 20,205/- ;
Annexure-B Rs. 60,375/- ;
Annexure-F Rs. 10,786/- ;
Other tests Rs. 88,500/- ;
Extra tests Rs. 59,881/- .
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.3.4(Performance under short-circuit conditions) |
- |
59800 |
|
59800/- For above 10kA and up to 50kA (Per shift)
40250/- For up to 10kA (Per shift) |
| 9.3.4.2.3(Verification of dielectric Withstand) |
- |
500 |
|
Not Applicable |
| 9.3.4.2.3(Leakage current Measurement) |
- |
500 |
|
Not Applicable |
| 9.3.3.1(Ambient air temperatur) |
- |
9919 |
|
9919/- For current above 200A and upto 1000A
3306/- For Current up to 200A |
| 9.3.3.3.2 (Measurement of the temperature of parts ) |
- |
9919 |
|
9919/- For current above 200A and upto 1000A
3306/- For Current up to 200A |
| 9.3.3.3.3( Temperature rise of a part ) |
- |
9919 |
|
9919/- For current above 200A and upto 1000A
3306/- For Current up to 200A |
| 9.3.3.3.4 (Temperature rise of the main circuit ) |
- |
9919 |
|
9919/- For current above 200A and upto 1000A
3306/- For Current up to 200A |
| 9.3.3.3.5( Temperature rise of control circuit) |
- |
9919 |
|
9919/- For current above 200A and upto 1000A
3306/- For Current up to 200A |
| 9.3.3.3.6( Temperature rise of coils and electromagnets ) |
- |
9919 |
|
9919/- For current above 200A and upto 1000A
3306/- For Current up to 200A |
| 9.3.3.3.7 (Temperature rise of auxiliary circuits ) |
- |
9919 |
|
9919/- For current above 200A and upto 1000A
3306/- For Current up to 200A |
| 9.3.3.4 (Dielectric properties ) |
- |
10286 |
|
Not Applicable |
| 9.3.3.4.1( Type tests ) |
- |
10286 |
|
Not Applicable |
| 9.3.5(Overload current withstand capability of contactors) |
- |
9200 |
|
9200/- For current above 1000A
7475/- For Current up to 1000A |
| 9.3.3.5("verification of rated making and breaking capacities, change-over ability and
reversibility, where applicable") |
- |
40250 |
|
40250/- For current above 1kA and up to 10kA (Per shift)
24150/- For Current up to 1kA |
| 9.3.3.6(verification of conventional operational performance) |
- |
40250 |
|
40250/- For current above 1kA and up to 10kA (Per shift)
25789/- For Current above 200A and up to 1000A
11903/- For Current up to 200A |
| 9.1.2, (i) (8.2.4 of IEC 60947-1:2007)(Mechanical properties of terminals) |
- |
2248 |
|
Not Applicable |
| 9.1.2 (j) (Annex C of IEC 60947-1)(verification of degrees of protection of enclosed contactors and starters) |
- |
6038 |
|
Not Applicable |
| 9.3.3.2(Operating limits) |
- |
13381 |
|
Not Applicable |
| 9.3.3.2.1(Power-operated equipment) |
- |
1852 |
|
Not Applicable |
| 9.3.3.2.1.2(Coil power consumption) |
- |
1852 |
|
Not Applicable |
| 9.3.3.2.2(Relays and releases) |
- |
9919 |
|
Not Applicable |
| 9.3.6.2(Operation and operating limits) |
- |
9919 |
|
Not Applicable |
| 9.3.6.3(Dielectric tests) |
- |
10286 |
|
Not Applicable |
| B.2(Mechanical durability) |
- |
20125 |
|
For 10000 operations and120 operating cycles per hour |
| B.3(Electrical durability) |
- |
40250 |
|
40250/- For current above 1kA and up to 10kA (Per shift)
25789/- For Current above 200A and up to 1000A
11903/- For Current up to 200A |
| F.7.2(Tests on products in a new condition) |
- |
10286 |
|
Not Applicable |
| F.7.3(Test after conventional operational performance) |
- |
500 |
|
Not Applicable |
| 9.4.2(Immunity) |
- |
61500 |
|
NA |
| 9.4.3(Emission) |
- |
27000 |
|
NA |
|
30 Nov, 2028 |
- Exclusion: Cl. 9.3.3.3.8 (Temperature rise of starting resistors for rheostatic rotor starters), Cl. 9.3.3.3.9 ( Temperature rise of the auto-transformer for two-step auto-transformer starters) |
| 82 |
IS 1709 (1984) |
Specification for capacitors or electric fan motors (First Revision) |
Up to 10 mfd |
97560 View breakup
Rs. 97,560/- (for all tests).
Type Test : Rs. 72,040/- ;
Routine Test for one capacitor: Rs. 4,560/-; Acceptance Test for one capacitor: Rs. 17,040/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 7.2(The capcitors shall be visually examined for finish and marking) |
- |
720 |
|
RS. |
| Cl. 7.3.1(Insualtion Resistance between terminal and container) |
- |
720 |
|
RS. |
| Cl. 7.3.2(Insulation Resistance between terminals) |
- |
720 |
|
RS. |
| Cl. 7.4.1(Capacitors shall be subjected to an ac voltage test as specified in Table 2.) |
- |
1200 |
|
RS. |
| Cl. 7.4.2(Capacitors shall be subjected for 10sec to a test between terminals and metal foil wrapped tightly around the surface of the container with s sinusoidal test voltages.
Test Voltage:2000Vrms for 10sec
During the test, no dielectric breakdown or flashover shall occur.
) |
- |
1200 |
|
RS. |
| Cl. 7.5(Capacitance measured at rated frequency and rated voltage.) |
- |
3000 |
|
RS. |
| Cl.7.6(Tangent of Loss Angle measured at rated frequency and rated voltage. The maximum value of the tangent of loss angle for Self-healing MPP Type.) |
- |
3000 |
|
RS. |
| Cl. 7.12(Unenergized capacitor units kept in a position most likely to reveal leakage and heated throughout so that all parts of the container reach the temperature 5ºC higher the maximum operating temperature value. Total heating and cooling cycle time shall be 8 hours. After the sealing test No leakage shall occure.) |
- |
2400 |
|
RS. |
| Cl. 7.13(Capacitance) |
- |
4800 |
|
RS. |
| Cl. 7.13(Change in capacitance at 0°C as compare to 27°C. (Limit: 3%Max.) ) |
- |
4800 |
|
RS. |
| Cl. 7.14.1(Before test capacitance shall be measured. Th capacitor shall be subjected for 10 seconds to an ac voltage of 1.5 ti9mes the rated voltage. If rewer than five breakdown occure during the time, The voltage shall be increased slowly until five breakdown occured until voltage occured 3.5 times the rated voltage. voltage reduced to 0.8 times, no breakdown is permitted after decreased of voltage.) |
- |
3000 |
|
RS. |
| Cl. 7.14.2(If only one or no breakdown has occurred since begning of the test when voltage has reached 3.5 times the rated voltage, the test shall be repeated on aonther identical capacitor.) |
- |
3000 |
|
RS. |
| Cl.7.14.3(Before and after the test,the cpacitance shall be measured, A chage not greater than 0.3 %in its value shall be allowec.) |
- |
3000 |
|
RS. |
| Cl. 7.15(After the test Capcitance variation) |
- |
12000 |
|
RS. |
| Cl. 7.16(The capacitors are mounted in a air circulated test chamber as specified and capacitors are energized at test voltage 1.25UN for 500hr Continuously at 50Hz. During the test no permanent breskdown,intertuption or flashover shall occure.) |
- |
18000 |
|
RS. |
| Cl. 7.17(The capacitor sample was mounted in a circulating air oven maintained at a temperature 10ºC above the maximum operating temperature as specified without energizing. Capacitor energized at 1.4 times rated voltage by applying test voltage between terminal for 1 h, then 1.6 times rated voltage for 1 h, then 1.8 times rated voltage for 1 h, then 2.0 times rated voltage for 1 h then switch off. Then 2.0 times the rated voltage for an 8 h period each in four cycles of 24h. After completion of the test, the capacito is consider to have passe destruction test if a) Current through it has not been interruped by the delayed action test circuit fuse or by any internal fuse. b) The currnt through it has been interrputed without any harmful effect occurring. c)Three delayed action test ciucuit fuse have cleared without any hamfu effect occurring.d) The endurance is entact at the end of test e) The test voltage between terminals and container is passed at the end of the test.) |
- |
21600 |
|
RS. |
| Cl. 7.7(A weight of 2kg shall be suspended freely from each one of them in turn for a period of 10 sec. There shall be no damage to the capacitor or termination after this loading.) |
- |
1960 |
|
RS. |
| Cl 7.8(Each termination shall withstand two consecutive bends as specified without damage to the capacitors) |
- |
1960 |
|
RS. |
| Cl 7.9(Soldering tags shall withstand two consecutive cycles of bending as specified without damage to the capacitors.) |
- |
1960 |
|
RS. |
| Cl. 7.10(There shall be no damage to the capacitors when the torque is applied to the nuts and screws of threaded terminations:) |
- |
0 |
|
Facility not available |
| Cl. 7.11(The capacitor shall be not suffer any damage when the specified soldering iron is applied to the termination of 15 sec.) |
- |
0 |
|
Facility not available |
|
30 Nov, 2028 |
- Except Cl. 7.10 & 7.11. |
| 83 |
IS 13730 : Part 8 (2014) |
Specification for particular types of winding wires: Part 8 polyesterimide enamelled round copper wire, class 180 (First Revision) |
- |
832000 View breakup
Rs. 8,32,000/- (For all tests)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Nominal Conductor diameter) |
- |
500 |
|
NA |
| 4(Conductor tollerance ) |
- |
500 |
|
NA |
| 4(Minimum increase
due to the insulation) |
- |
500 |
|
NA |
| 4(Maximum overall
diameter) |
- |
500 |
|
NA |
| 5(Electrical resistance) |
- |
600 |
|
NA |
| 6(Elongation) |
- |
600 |
|
NA |
| 7(Springiness) |
- |
500 |
|
NA |
| 8(Flexibility and adherence) |
- |
900 |
|
NA |
| 8(Stretching test (nominal conductor diameters over 1,600 mm)) |
- |
0 |
|
Charges included in Flexibility and adherence test |
| 8(Jerk test (nominal conductor diameters up to and including 1,000 mm)) |
- |
0 |
|
Charges included in Flexibility and adherence test |
| 8(Peel test (nominal conductor diameters over 1,000 mm)) |
- |
0 |
|
Charges included in Flexibility and adherence test |
| 9( Heat shock) |
- |
800 |
|
Na |
| 10( Cut-through) |
- |
850 |
|
NA |
| 11(Resistance to abrasion :Minimum average force to failure
) |
- |
850 |
|
NA |
| 12(Resistance to solvents) |
- |
850 |
|
NA |
| 13(Breakdown voltage ) |
- |
1800 |
|
NA |
| 14(Continuity of insulation ) |
- |
650 |
|
NA |
| 15(Temperature index) |
- |
821600 |
|
NA |
|
30 Nov, 2028 |
- Except Cl. No. 16 & 23. |
| 84 |
IS 13774 (2021) |
Live Working Gloves of Insulating Material (Second Revision) |
- |
48050 View breakup
Rs. 48,050/- (for type test)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.2.3(Thickness) |
- |
2900 |
|
NA |
| 8.3.1(Tensile strength and elongation at break) |
- |
1800 |
|
NA |
| 8.3.2(Resistance to mechanical puncture) |
- |
800 |
|
NA |
| 8.3.3(Tension set) |
- |
800 |
|
NA |
| 8.4(Dielectric tests) |
- |
5400 |
|
NA |
| 8.4.2.1(AC proof test) |
- |
3000 |
|
Na |
| 8.5(Ageing test) |
- |
15250 |
|
NA |
| 8.6(Thermal tests) |
- |
7800 |
|
NA |
| 8.7(Tests on gloves with special properties) |
- |
10300 |
|
NA |
| 4.3.3(Thickness) |
- |
1450 |
|
NA |
| 5.5.2(IS 13774) |
- |
800 |
|
NA |
| 5.5.3(IS 13774) |
- |
800 |
|
NA |
| 5.5.4(IS 13774) |
- |
800 |
|
NA |
| 5.6.1.4(Voltage dielectric test procedure) |
- |
2050 |
|
NA |
| 5.6.1.4.2(Proof test) |
- |
1300 |
|
NA |
| 5.7(Ageing test) |
- |
9650 |
|
nA |
| 5.8.1(Low temperature test) |
- |
4800 |
|
NA |
| 5.9.1(IS 13774) |
- |
5500 |
|
NA |
| 5.6.1.4.2(IS 13774) |
- |
1300 |
|
NA |
| 5.9.2(IS 13774) |
- |
4800 |
|
Na |
| 5.9.3(IS 13774) |
- |
2050 |
|
na |
| 5.9.4(IS 13774) |
- |
6600 |
|
NA |
|
30 Nov, 2028 |
- Except Cl. No. 5.9.5.1 Leakage current resistance. |
| 85 |
IS 7098 : Part 3 (1993) |
Cross - Linked polyethylene insulated thermoplastic sheathed cables - Specification: Part 3 for working voltages from 66 kV up to and including 220 kV |
- |
589500 View breakup
Rs. 5,89,500/- for 1 core (upto 66 kV) ;
Multicore cables: additional charges Rs. 500/- per core per test.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 18.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
1600 |
|
- |
| 18.3.1(Thickness of Outer Sheath : armoured Cables) |
- |
1600 |
|
- |
| 19.1 A) I)(Tests on conductor : Annealing test ( for copper )) |
- |
900 |
|
- |
| 19.1 A) II)(Tests on conductor : Resistance test) |
- |
1300 |
|
- |
| 19.1 b) I)(Test for thickness and dimensions of insulation) |
- |
1600 |
|
- |
| 19.1 b) II)(Tensile strength and elongation at break) |
- |
2000 |
|
- |
| 19.1 b) III)(Thermal ageing in air oven) |
- |
8600 |
|
- |
| 19.1 b) IV)(Hot set test) |
- |
1500 |
|
- |
| 19.1 b) V)(Shrinkage test) |
- |
1300 |
|
- |
| 20.3(Test for concentric metallic screen : Test for concentric copper wire) |
- |
2500 |
|
- |
| 20.4(Test for concentric copper tape) |
- |
2500 |
|
- |
| 20.5(Thickness of metallic sheath) |
- |
1600 |
|
- |
| 20.6(Tests for armouring material : Dimensions) |
- |
5000 |
|
- |
| 19.1 f) II)(Tests for armouring material : Tensile strength and elongation at break) |
- |
5000 |
|
- |
| Table 9, (Measurement of thickness) |
- |
1600 |
|
- |
| 19.1 g)2) i)(PVC sheath : Tensile strength and elongation at break) |
- |
2000 |
|
- |
| 19.1 g)2) iii)(PVC sheath : Loss of mass) |
- |
8600 |
|
- |
| 19.1 g)2) v)(PVC sheath : Hot deformation test) |
- |
1900 |
|
- |
| 19.1 g)2) vi)(PVC sheath : Shrinkage test) |
- |
1300 |
|
- |
| 19.1 g)2) vii)(PVC sheath : Thermal stability) |
- |
1900 |
|
- |
| 19.1 g)3) ii)(PE sheath : Tensile strength and elongation at break before and after ageing) |
- |
2000 |
|
- |
| 19.1 g)3) iii)(PE sheath : Hot-detormation) |
- |
1900 |
|
- |
| 20.7(Flammabihty test ( for PVC outer
sheathed cables only )) |
- |
1500 |
|
- |
| 20.9.1(Thermal ageing on complete cable sample) |
- |
10300 |
|
- |
| 19.1 k) ii)(Tensile strength and elongation at breakfor insulation and outer sheath) |
- |
2000 |
|
- |
| 20.2(Resistivity test for semi-conducting layer) |
- |
11000 |
|
- |
| 20.11.1(Bending test followed by P D test) |
- |
5000 |
|
- |
| 20.12, 20.18(Dielectric power factor and capacitance measurement at ambient temperature) |
- |
20000 |
|
- |
| 20.13(Dielectric power factor measurement at elevated temperature) |
- |
25000 |
|
- |
| 20.14.1(Load cycle test followed by P.D measurement) |
- |
300000 |
|
- |
| 20.15(Impulse Voltage Test Followed by High Voltage Test) |
- |
40000 |
|
- |
| 20.8.3(Water tightness test) |
- |
45000 |
|
- |
| 20.16.1(Test for Dimensions of Insulation : Insulation Thickness) |
- |
1600 |
|
- |
| 20.16.2(Test for Dimensions of Insulation : Test for Eccentricity) |
- |
1600 |
|
- |
| 20.16.3(Test for Dimensions of Insulation : Test for Ovality) |
- |
1600 |
|
- |
| 20.17(High Voltage Test ( as Routine and
Acceptance Tests ) ) |
- |
10000 |
|
- |
| 4.1(CONDUCTOR) |
- |
1550 |
|
- |
| 12.1(CONDUCTOR SCREENING ) |
- |
1550 |
|
- |
| 17.1(ARMOUR) |
- |
1550 |
|
- |
| 8.1(INNER SHEATH) |
- |
1550 |
|
- |
| 14.1(INSULATION SCREENING) |
- |
1550 |
|
- |
| 5(INSULATION) |
- |
1550 |
|
- |
| 15.1(MOISTURE BARRIER) |
- |
1550 |
|
- |
| 10.1(OUTER SHEATH) |
- |
1550 |
|
For constructional details Rs.1550 |
|
30 Nov, 2028 |
- - |
| 86 |
IS 9968 : Part 2 (2002) |
Specification for elastomer - Insulated cables: Part 2 for working voltages from 3.3 kV up to and including 33 kV (First Revision) |
- |
255950 View breakup
Rs. 1,85,847/- for 1 core (upto 11 kV) ;
Rs. 1,95,297/- for 1 core (above 11 kV) ;
Rs. 2,20,497/- for 3 core (upto 11 kV) ;
Rs. 2,55,950/- for 3 core (above 11 kV) ;
Multicore cables: additional charges Rs. 500/- per core per test.
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 22.1 a)1)(Annealing test
(for copper) - IS 10810: Part 1) |
- |
600 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 a)2)(Tensile test
(for aluminium) -IS 10810: Part 2) |
- |
600 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 a)3)(Wrapping Test
(for aluminium) - IS 10810: Part 3) |
- |
500 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 a)4)(Conductor resistance
test) |
- |
1300 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 a)5)(Persulphate test
(tinned copper
conductor)- IS 10810: Part 4) |
- |
1500 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 b)1)(Test for Galvanized Steel
Wires/Formed Wires
1) Dimensions -IS 10810: Part 36) |
- |
714.28 |
|
- |
| 22.1 b)2)i)(Test for Galvanized Steel
Wires/Formed Wires
2) Tensile Strentgh -IS 10810: Part 37) |
- |
714.28 |
|
- |
| 22.1 b)2)ii)(Test for Galvanized Steel
Wires/Formed Wires
2) Elongation at break -IS 10810: Part 37) |
- |
714.28 |
|
- |
| 22.1 b)2)iii)(Test for Galvanized Steel
Wires/Formed Wires
3) Torsion (for round
wires only) -IS 10810: Part 38) |
- |
714.28 |
|
- |
| 22.1 b)2)iv)(Test for Galvanized Steel
Wires/Formed Wires
4) Winding (for strips
only) -IS 10810: Part 39) |
- |
714.28 |
|
- |
| 22.1 b)2)v)(Test for Galvanized Steel
Wires/Formed Wires
5) Zinc coating : Uniformity-IS 10810: Part 40) |
- |
714.28 |
|
- |
| 22.1 b)2)vi)(Test for Galvanized Steel
Wires/Formed Wires
5) Zinc coating : Mass -IS 10810: Part 41) |
- |
714.28 |
|
- |
| 22.1 b)2) vii) (Resistivity - IS 10810: Part 42) |
- |
714.28 |
|
- |
| 22.1 c)2)(Physical Tests for
Insulation : Tensile Strenth - IS 10810: Part 7) |
- |
1000 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 c)2)(Physical Tests for
Insulation : Elongation - IS 10810: Part 7) |
- |
1000 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 c)2)(Physical Tests for
Sheath : Tensile Strenth - IS 10810: Part 7) |
- |
1000 |
|
- |
| 22.1 c)2)(Physical Tests for
Sheath : Elongation - IS 10810: Part 7) |
- |
1000 |
|
- |
| 22.1 c)3)(Physical Tests for
Insulation ( Ageing in air oven): Tensile Strenth - IS 10810: Part 11) |
- |
1000 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 c)3)(Physical Tests for
Insulation ( Ageing in air oven): Tensile Strenth Variation - IS 10810: Part 12) |
- |
3300 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 c)3)(Physical Tests for
Insulation( Ageing in air oven) : Elongation - IS 10810: Part 11) |
- |
1000 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 c)3)(Physical Tests for
Insulation( Ageing in air oven) : Elongation variation - IS 10810: Part 12) |
- |
3300 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 c)3)(Physical Tests for
Sheath( Ageing in air oven) : Tensile Strenth - IS 10810: Part 11) |
- |
1000 |
|
- |
| 22.1 c)3)(Physical Tests for
Sheath( Ageing in air oven) : Tensile Strenth variation - IS 10810: Part 12) |
- |
3300 |
|
- |
| 22.1 c)3)(Physical Tests for
Sheath ( Ageing in air oven): Elongation - IS 10810: Part 11) |
- |
1000 |
|
- |
| 22.1 c)3)(Physical Tests for
Sheath ( Ageing in air oven): Elongation variation - IS 10810: Part 12) |
- |
3300 |
|
- |
| 22.1 c)4)(Physical Tests for
Insulation ( Ageing in air bomb): Tensile Strenth variation - IS 10810: Part 56) |
- |
1300 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 c)4)(Physical Tests for
Insulation( Ageing in air bomb) : Elongation variation - IS 10810: Part 56) |
- |
1300 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 c)4)(Physical Tests for
Sheath(Ageing in air bomb) : Tensile Strenth variation - IS 10810: Part 56) |
- |
1300 |
|
- |
| 22.1 c)4)(Physical Tests for
Sheath ( Ageing in air bomb): Elongation variation - IS 10810: Part 56) |
- |
1300 |
|
- |
| 22.1 c)5)(Physical Tests for
Insulation :Hot set Elongation - IS 10810: Part 30) |
- |
650 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 c)5)(Physical Tests for
Insulation :Permanent set - IS 10810: Part 30) |
- |
650 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 c)5)(Physical Tests for
Sheath :Hot set Elongation - IS 10810: Part 30) |
- |
650 |
|
- |
| 22.1 c)5)(Physical Tests for
Sheath :Permanent set - IS 10810: Part 30) |
- |
650 |
|
- |
| 22.1 c)6)(Physical Tests for
Sheath(Oil resistance test) : Tensile Strenth Variation - IS 10810: Part 31) |
- |
1000 |
|
- |
| 22.1 c)6)(Physical Tests for
Sheath ( Oil resistance test): Elongation Variation - IS 10810: Part 31) |
- |
1000 |
|
- |
| 22.1 c)7)(Tear Resistance test - IS 10810: Part 17) |
- |
1000 |
|
- |
| 22.1 c)8)(Shrinkage : Insulation - IS 10810: Part 12) |
- |
1300 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 c)8)(Shrinkage test- Crack observed : Insulation - IS 10810: Part 13) |
- |
1300 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 c)8)(Shrinkage test : Sheath - IS 10810: Part 12) |
- |
1300 |
|
- |
| 22.1 c)9)(Hot deformation test : Sheath - IS 10810: Part 15) |
- |
1900 |
|
- |
| 22.1 c)10)(Loss of mass in air
oven : Sheath - IS 10810: Part 10) |
- |
8600 |
|
- |
| 22.1 c)11)(Heat shock : Sheath - IS 10810: Part 14) |
- |
1200 |
|
- |
| 22.1 c)12)(Thermal stability : Sheath - IS 10810: Part 60) |
- |
1900 |
|
- |
| 22.1 d)(Insulation Resistance Test: Volume resistivity ) |
- |
1350 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 d)(Insulation Resistance Test: Insulation resistance constant ) |
- |
1350 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 n)(Flammability) |
- |
1500 |
|
- |
| 22.1 e)(Partial Discharge Test) |
- |
10500 |
|
RS. 5250 for single core
RS. 10500 for three core |
| 22.1 f)(Bending Test Followed by
Partial Discharge Test) |
- |
3150 |
|
Rs. 2100 for Single core
Rs. 3150 for three core |
| 22.1 g)(Dielectric Power Factor
Test
1) As a function of Voltage) |
- |
10500 |
|
Rs. 5250 for single core
Rs. 10500 for Three core |
| 22.1 g)(Dielectric Power Factor
Test
1) As a function of
temperature) |
- |
12600 |
|
Rs. 8400 for single core
Rs. 12600 for three core |
| 22.1 h)(Heating Cycle Test) |
- |
8400 |
|
- |
| 22.1 k)(High Voltage Test
for Four Hours) |
- |
6300 |
|
Rs.3150 for single core
Rs. 6300 for Three core |
| 22.1 m)(Water Absorption Test - IS 10810: Part 28) |
- |
11900 |
|
Additional charges per core per test :Rs. 500 |
| 22.1 j)(Impulse Withstand Test) |
- |
27300 |
|
Rs. 27300 upto 11 kV
Rs. 36750 above 11 kV |
|
30 Nov, 2028 |
- - |
| 87 |
IS 7809 : Part 3 : Sec 1 (1986) |
Specification for pressure sensitive adhesive insulating tapes for electrical purposes: Part 3 requirements or individual materials: Sec 1 plasticized polyvinylchloride tapes with non - Thermosetting adhesive (First Revision) |
- |
37685.50 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3.2(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
-- |
| 3.3(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
-- |
| 3.4(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
-- |
| 4.1(Performance Requirments) |
- |
0 |
|
-- |
| 4.2(Performance Requirments) |
- |
0 |
|
-- |
| 4.3(Performance Requirments) |
- |
0 |
|
-- |
| 4.4(Performance Requirments) |
- |
0 |
|
-- |
| 4.5(Performance Requirments) |
- |
0 |
|
-- |
| 4.6(Flammability ,Cl 6 of IS 7809 (Part 2): 1977) |
- |
0 |
|
-- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
-- |
| 4.8(Stability to accelerated ageing ) |
- |
0 |
|
-- |
| 4.9(Insulation resistance test) |
- |
0 |
|
-- |
| 3.2(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
-- |
| 3.3(General Requirments,as per IS 7809 (Part 1 ) :1975 ) |
- |
0 |
|
-- |
| 4.5(Performance Requirments) |
- |
0 |
|
-- |
| 4.7(Electrolytic corrosion) |
- |
0 |
|
-- |
| 4.8(Stability to accelerated ageing ) |
- |
0 |
|
-- |
| 4.9(Insulation resistance test) |
- |
0 |
|
-- |
| Cl.No.4 of IS 7809 (Part 1)-1975(Appearance) |
- |
0 |
|
-- |
| Cl.No.5 of IS 7809 (Part 1)-1975(Freedom From Deffects) |
- |
0 |
|
-- |
| Cl.No.3.2(Width) |
- |
575 |
|
-- |
| Cl.No.3.3(Length) |
- |
575 |
|
-- |
| Cl.No.3.4(Thickness) |
- |
575 |
|
-- |
| Cl.No.4.1(Tensile Strength) |
- |
1058 |
|
-- |
| Cl.No.4.2(Adhesion to Steel) |
- |
690 |
|
-- |
| Cl.No.4.3(Adhesion to backing) |
- |
690 |
|
-- |
| Cl.No.4.4(Electric Strength at RT) |
- |
1150 |
|
-- |
| Cl.No.4.5(Electric Strength after Humid Conditioning) |
- |
1955 |
|
-- |
| Cl.No.4.6(Flammability) |
- |
920 |
|
-- |
| Cl.No.4.7() |
- |
19722.50 |
|
-- |
| Cl.No.4.8(Stability to accelerated ageing) |
- |
7475 |
|
-- |
| Cl.No.4.9(Insulation Resistance) |
- |
2300 |
|
-- |
| Cl.No.7 of IS 7809 (Part 1)-1975(Minimum Storage Life) |
- |
0 |
|
-- |
| Cl.No.4 of IS 7809 (Part 1)-1975(Appearance after minimum storage Life) |
- |
0 |
|
-- |
| Cl.No.5 of IS 7809 (Part 1)-1975(Freedom From Deffects after minimum storage Life) |
- |
0 |
|
-- |
| Cl.No.3.2(Width after minimum storage Life) |
- |
0 |
|
-- |
| Cl.No.3.3(Length after minimum storage Life) |
- |
0 |
|
-- |
| Cl.No.3.4(Thickness after minimum storage Life) |
- |
0 |
|
-- |
| Cl.No.4.1(Tensile Strength after minimum storage Life) |
- |
0 |
|
-- |
| Cl.No.4.2(Adhesion to Steel after minimum storage Life) |
- |
0 |
|
-- |
| Cl.No.4.3(Adhesion to backing after minimum storage Life) |
- |
0 |
|
-- |
| Cl.No.4.4(Electric Strength at RT after minimum storage Life) |
- |
0 |
|
-- |
| Cl.No.4.5(Electric Strength after Humid Conditioning after minimum storage Life) |
- |
0 |
|
-- |
| Cl.No.4.6(Flammability after minimum storage Life) |
- |
0 |
|
-- |
| Cl.No.4.7(Electrolytic Corrosion after minimum storage Life) |
- |
0 |
|
-- |
| Cl.No.4.8(Stability to accelerated ageing after minimum storage Life) |
- |
0 |
|
-- |
| Cl.No.4.9(Insulation Resistance after minimum storage Life) |
- |
0 |
|
-- |
|
30 Nov, 2028 |
- - |
| 88 |
IS 4253 : Part 2 (2008) |
Cork composition sheets - Specification: Part 2 cork and rubber (Second Revision) |
All Type |
14605 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.No.4(Thickness) |
- |
575 |
|
- |
| Cl.No.8.3(Dimensional Stability) |
- |
1380 |
|
- |
| Cl.No.8.4(Tensile strength) |
- |
920 |
|
- |
| Cl.No.8.5(Compressibility and Recovery) |
- |
1725 |
|
- |
| Cl.No.8.6(Compression Set) |
- |
1380 |
|
- |
| Cl.No.8.7(Flexibility) |
- |
575 |
|
- |
| Cl.No.8.8(Fluid Resistance Test) |
- |
2300 |
|
- |
| Cl.No.8.9(Chemical test on water Extract - pH) |
- |
1725 |
|
- |
| Cl.No.8.9(Chemical test on water Extract - Chloride content) |
- |
1725 |
|
- |
| Cl.No.8.9(Chemical test on water Extract - Sulphate content) |
- |
1725 |
|
- |
| Cl.No.6 (Table 1, Sr.No.1 (i)(Hardness) |
- |
575 |
|
- |
|
30 Nov, 2028 |
- - |
| 89 |
IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
- |
22800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
0 |
|
--- |
| 6(Classification- IS 302-1) |
- |
0 |
|
--- |
| 7.1(Marking- IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.2(Marking) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.4(Marking) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.5(Marking) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 7.6(Marking) |
- |
0 |
|
Total Test charge for cl. no. 7 is Rs. 500/- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 8 is Rs. 500/- |
| 9(Starting, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 9 is Rs. 500/- |
| 10(Power Input and Current, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 10 is Rs. 500/- |
| 11(Heating, IS 302-1) |
- |
750 |
|
Total Test charge for cl. no. 11 is Rs. 750/- |
| 11(Heating, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 11 is Rs. 750/- |
| 11(Heating, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 11 is Rs. 750/- |
| 11(Heating, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 11 is Rs. 750/- |
| 11(Heating, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 11 is Rs. 750/- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 13 is Rs. 500/- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 13 is Rs. 500/- |
| 14(Transient Over Voltages, IS 302-1) |
- |
0 |
|
--- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
2450 |
|
Total Test charge for cl. no. 15 is Rs. 2450/- |
| 15.2(Moisture Resistance-Spillage test) |
- |
0 |
|
Total Test charge for cl. no. 15 is Rs. 2450/- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 16 is Rs. 500/- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 16 is Rs. 500/- |
| 19(Abnormal Operation, IS 302-1) |
- |
650 |
|
Total Test charge for cl. no. 19 is Rs. 650/- |
| 19(Abnormal Operation, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 19 is Rs. 650/- |
| 19(Abnormal Operation, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 19 is Rs. 650/- |
| 19(Abnormal Operation, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 19 is Rs. 650/- |
| 20(Stability & Mechanical Hazards, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 20 is Rs. 500/- |
| 20(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 20 is Rs. 500/- |
| 21(Mechanical Strength, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 21 is Rs. 500/- |
| 21(Mechanical Strength, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 21 is Rs. 500/- |
| 22.1(Construction, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 22 is Rs. 500/- |
| 22.2(Construction) |
- |
0 |
|
Total Test charge for cl. no. 22 is Rs. 500/- |
| 22.3(Construction) |
- |
0 |
|
Total Test charge for cl. no. 22 is Rs. 500/- |
| 22.4(Construction) |
- |
0 |
|
Total Test charge for cl. no. 22 is Rs. 500/- |
| 22.5(Construction) |
- |
0 |
|
Total Test charge for cl. no. 22 is Rs. 500/- |
| 22.6(Construction) |
- |
0 |
|
Total Test charge for cl. no. 22 is Rs. 500/- |
| 22.8(Construction) |
- |
0 |
|
Total Test charge for cl. no. 22 is Rs. 500/- |
| 22.9(Construction) |
- |
0 |
|
Total Test charge for cl. no. 22 is Rs. 500/- |
| 22.1(Construction) |
- |
0 |
|
Total Test charge for cl. no. 22 is Rs. 500/- |
| 23(Internal Wiring, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 23 is Rs. 500/- |
| 23(Internal Wiring, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 23 is Rs. 500/- |
| 23(Internal Wiring, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 23 is Rs. 500/- |
| 23(Internal Wiring, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 23 is Rs. 500/- |
| 23(Internal Wiring, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 23 is Rs. 500/- |
| 23(Internal Wiring, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 23 is Rs. 500/- |
| 23(Internal Wiring, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 23 is Rs. 500/- |
| 23(Internal Wiring, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 23 is Rs. 500/- |
| 24.1(Components, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 24 is Rs. 500/- |
| 24.1(Components, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 24 is Rs. 500/- |
| 24.1(Components, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 24 is Rs. 500/- |
| 24.2(Components) |
- |
0 |
|
Total Test charge for cl. no. 24 is Rs. 500/- |
| 24.4(Components) |
- |
0 |
|
Total Test charge for cl. no. 24 is Rs. 500/- |
| 24.5(Components) |
- |
0 |
|
Total Test charge for cl. no. 24 is Rs. 500/- |
| 24.7(Components) |
- |
0 |
|
Total Test charge for cl. no. 24 is Rs. 500/- |
| 24.8(Components) |
- |
0 |
|
Total Test charge for cl. no. 24 is Rs. 500/- |
| 24.9(Components) |
- |
0 |
|
Total Test charge for cl. no. 24 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 25 is Rs. 500/- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 26 is Rs. 500/- |
| 27(Provision for Earthing, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 27 is Rs. 500/- |
| 27(Provision for Earthing, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 27 is Rs. 500/- |
| 27(Provision for Earthing, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 27 is Rs. 500/- |
| 27(Provision for Earthing, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 27 is Rs. 500/- |
| 27(Provision for Earthing, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 27 is Rs. 500/- |
| 28(Screws & Connections, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 28 is Rs. 500/- |
| 29(Clearances and Distances through Insulation, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 29 is Rs. 500/- |
| 29(Clearances and Distances through Insulation, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 29 is Rs. 500/- |
| 30(Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
4650 |
|
Total Test charge for cl. no. 30 is Rs. 4650/- |
| 30(Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
0 |
|
Total Test charge for cl. no. 30 is Rs. 4650/- |
| 31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
Total Test charge for cl. no. 31 is Rs. 500/- |
| Cl.32(Radiation, toxicity and similar hazards) |
- |
0 |
|
--- |
| 34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
1900 |
|
Total Test charge for cl. no. 34 is Rs. 1900/- |
| 34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
0 |
|
Total Test charge for cl. no. 34 is Rs. 1900/- |
| 34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
0 |
|
Total Test charge for cl. no. 34 is Rs. 1900/- |
| 34.3(Whisking egg whites ) |
- |
0 |
|
Total Test charge for cl. no. 34 is Rs. 1900/- |
| 34.4(IDLI batter-Grinding of black gram) |
- |
0 |
|
Total Test charge for cl. no. 34 is Rs. 1900/- |
| 34.4(IDLI batter-Grinding of rice) |
- |
0 |
|
Total Test charge for cl. no. 34 is Rs. 1900/- |
| 34.4(IDLI batter-Grinding of rice) |
- |
0 |
|
Total Test charge for cl. no. 34 is Rs. 1900/- |
| 34.4(IDLI batter-Grinding of rice) |
- |
0 |
|
Total Test charge for cl. no. 34 is Rs. 1900/- |
| 34.5.1 (a)(Operational test for juicers ) |
- |
0 |
|
Total Test charge for cl. no. 34 is Rs. 1900/- |
| 34.5.1 (b)(Operational test for juicers ) |
- |
0 |
|
Total Test charge for cl. no. 34 is Rs. 1900/- |
| 34.5.2(Operational test for juicers ) |
- |
0 |
|
Total Test charge for cl. no. 34 is Rs. 1900/- |
| 35(Temperature withstand test for bowl) |
- |
500 |
|
Total Test charge for cl. no. 35 is Rs. 500/- |
| 36(Test for controls ) |
- |
500 |
|
Total Test charge for cl. no. 36 is Rs. 500/- |
| 37(Strength of Assembly ) |
- |
500 |
|
Total Test charge for cl. no. 37 is Rs. 500/- |
| 37(Strength of Assembly ) |
- |
0 |
|
Total Test charge for cl. no. 37 is Rs. 500/- |
| Cl.18(Endurance) |
- |
1900 |
|
--- |
| Cl.14(Transient Over voltage) |
- |
0 |
|
--- |
|
30 Nov, 2028 |
- - |
| 90 |
IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
Electric kitchen Machine |
16700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
0 |
|
--- |
| 6(Classification- IS 302-1) |
- |
0 |
|
--- |
| 7.1(Marking- IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 7.101(Marking) |
- |
0 |
|
Total test charge for cl. no. 7 is Rs. 360/- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 8 is Rs. 360/- |
| 10(Power Input and Current, IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 10 is Rs. 360/- |
| 11(Heating, IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 11 is Rs. 360/- |
| 11(Heating, IS 302-1) |
- |
0 |
|
Total test charge for cl. no.. 11 is Rs. 360/- |
| 11(Heating, IS 302-1) |
- |
0 |
|
Total test charge for cl. no.. 11 is Rs. 360/- |
| 11(Heating, IS 302-1) |
- |
0 |
|
Total test charge for cl. no.. 11 is Rs. 360/- |
| 11(Heating, IS 302-1) |
- |
0 |
|
Total test charge for cl. no.. 11 is Rs. 360/- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 13 is Rs. 360/- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
Total test charge for cl. no.. 13 is Rs. 360/- |
| 14(Transient Over Voltages, IS 302-1) |
- |
4650 |
|
--- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
1750 |
|
Total test charge for cl. no.. 15 is Rs. 1750/- |
| 15.2(Moisture Resistance, IS 302-1) |
- |
0 |
|
Total test charge for cl. no.. 15 is Rs. 1750/- |
| 15(Moisture Resistance, IS 302-1) |
- |
0 |
|
Total test charge for cl. no.. 15 is Rs. 1750/- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
360 |
|
Total test charge for cl. no.. 16 is Rs. 360/- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
Total test charge for cl. no.. 15 is Rs. 1750/- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
1360 |
|
Total test charge for cl. no.. 17 is Rs. 1360/- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
Total test charge for cl. no.. 17 is Rs. 1360/- |
| 19.7(Abnormal Operation, IS 302-1) |
- |
465 |
|
Total test charge for cl. no.. 19 is Rs. 465/- |
| 19.8(Abnormal Operation, IS 302-1) |
- |
0 |
|
Total test charge for cl. no.. 19 is Rs. 465/- |
| 19.9(Abnormal Operation, IS 302-1) |
- |
0 |
|
Total test charge for cl. no.. 19 is Rs. 465/-- |
| 19.101(Abnormal Operation) |
- |
0 |
|
Total test charge for cl. no.. 19 is Rs. 465/- |
| 19.102(Abnormal Operation) |
- |
0 |
|
Total test charge for cl. no.. 19 is Rs. 465/- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.101(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.102(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.103(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.104(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.105(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.106(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.107(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.108(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.109(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.110(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.111(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.112(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.113(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.114(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.115(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 20.116(Stability & Mechanical Hazards) |
- |
0 |
|
Total test charge for cl. no. 20 is Rs. 360/- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 21 is Rs. 360/- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 21 is Rs. 360/- |
| 22(Construction, IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 22 is Rs. 360/- |
| 22.101(Construction) |
- |
0 |
|
Total test charge for cl. no. 22 is Rs. 360/- |
| 22.102(Construction) |
- |
0 |
|
Total test charge for cl. no. 22 is Rs. 360/- |
| 23.1(Internal Wiring, IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 23 is Rs. 360/- |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 23 is Rs. 360/- |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 23 is Rs. 360/- |
| 23.4(Internal Wiring, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 23 is Rs. 360/- |
| 23.5(Internal Wiring, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 23 is Rs. 360/- |
| 23.6(Internal Wiring, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 23 is Rs. 360/- |
| 23.7(Internal Wiring, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 23 is Rs. 360/- |
| 23.8(Internal Wiring, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 23 is Rs. 360/- |
| 23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 23 is Rs. 360/- |
| 23.10(Internal Wiring, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 23 is Rs. 360/- |
| 24.1(Components, IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 24 is Rs. 360/- |
| 24.2(Components, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 24 is Rs. 360/- |
| 24.5(Components, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 24 is Rs. 360/- |
| 24.6(Components, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 24 is Rs. 360/- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 25 is Rs. 360/- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 26 is Rs. 360/- |
| 27(Provision for Earthing, IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 27 is Rs. 360/- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 27 is Rs. 360/- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 27 is Rs. 360/- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 27 is Rs. 360/- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 27 is Rs. 360/- |
| 28(Screws & Connections, IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 28 is Rs. 360/- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 29 is Rs. 360/- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 29 is Rs. 360/- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
1995 |
|
Total test charge for cl. no. 30 is Rs. 1995/- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
Total test charge for cl. no. 30 is Rs. 1995/- |
| 31(Resistance of Rusting, IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 31 is Rs. 360/- |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
360 |
|
Total test charge for cl. no. 32 is Rs. 360/- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
--- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
--- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
--- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
--- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
--- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
--- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
--- |
|
30 Nov, 2028 |
- Exclude Cl. No. 19.11.4.7 as per IS 302-2-14. |