391 |
IS 12823 (2015) |
Prelaminated Particle Boards from Wood and other Lignocellulosic Material - Specification ( First Revision ) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 10.13 & Annex F ( Test For Resistance to Cigarette Burn) |
- |
|
|
|
Cl 10.12 & Annex E ( Test For Crack Resistance) |
- |
|
|
|
Cl 10.9 (Test For Screw Withdrawal Strength) |
- |
|
|
|
Cl 10.8 (For Determination of Tensile Strength Perpendicular to Surface After Ageing Test) |
- |
|
|
|
Cl 10.7 (For Determination of Tensile Strength Perpendicular to Surface) |
- |
|
|
|
Cl 10.6 (Tesr For Modulus Of Elasticity & Mudulus Of Rupture) |
- |
|
|
|
Cl 10.5 (For Swelling in water Test ) |
- |
|
|
|
Cl 10.4 (For Water AbsorptionTest ) |
- |
|
|
|
Cl 10.3 (Test For Moisture Content) |
- |
|
|
|
Cl 10.2 (Test For Density) |
- |
|
|
|
Cl 8 (Dimensions & Tolerances) |
- |
|
|
|
Cl 7 (Finish) |
- |
|
|
|
Cl 6 (Manufacture) |
- |
|
|
|
|
Partial
|
|
- |
Sample Test Parameter not available in CL:
"10.4 Test for Water Absorption, 10.5 Test for Swelling in Water, 10.6 Test for Modulus of Rupture (MOR)
and Modulus of Elasticity (MOE), 10.8 Test for Tensile Strength Perpendicular
to Surface After Ageing, 10.10 Test for Abrasion Resistance, 10.11 Test for Resistance to Steam, 10.14 Test for Resistance to Stain."
SIZE: One Board For All Tests
Sample Size without dimensional measurements:Length-1200 mm, width-1200 |
392 |
IS 8808 (2019) |
Burners for oil pressure stoves and oil pressure heaters - Specification (Third Revision) |
- |
-
|
Rs. 6600/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (TYPES) |
- |
|
|
|
6.1 (SHAPE, SIZES AND DIMENSIONS - FIG. 1A,1B AND 2) |
- |
|
|
|
6.1 (SHAPE, SIZES AND DIMENSIONS - FIG. 3A,3B AND 3C) |
- |
|
|
|
8 (FINISH) |
- |
|
|
|
10.1 (TESTS-Pressure Tests) |
- |
|
|
|
10.2 (TESTS-Tests for Thermal Efficiency) |
- |
|
|
|
5 (MATERIALS- Roarer type
burner) |
- |
|
|
|
5 (MATERIALS-Silencer type
burner) |
- |
|
|
|
5 (MATERIALS- Tube type
burner) |
- |
|
|
|
|
Partial
|
|
- |
EXCLUDING "-; 10.2 -Thermal Efficiency,10.1 -Pressure Tests," |
393 |
IS 9762 (1994) |
Specification for polyethylene floats (Spherical) for float valves |
- |
-
|
Rs.4500/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
cl 8.1 (Leakage & water ab. Test) |
- |
|
|
|
cl 8.2 (Deflection Test) |
- |
|
|
|
cl 8.3 (Impact test) |
- |
|
|
|
cl 8.4 (Boss test) |
- |
|
|
|
|
Partial
|
|
- |
- |
394 |
IS 3989 (2009) |
Centrifugally cast (Spun) iron spigot and socket soil, waste, ventilating and rainwater pipes, fittings and accessories - Specification (Third Revision) |
- |
-
|
Rs. 3600/- and Material testing charges as per relevant View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5 (Hydrostatic Test) |
- |
|
|
|
6.2,6.3, Table 1 & 4 (Dimensions & Tolerances, mm) |
- |
|
|
|
6.2,6.3, Table 1 & 4 (Equal branches without access door,mm) |
- |
|
|
|
6.2,6.3, Table 1 & 4 (Barrel) |
- |
|
|
|
6.2,6.3, Table 1 & 4 (Socket) |
- |
|
|
|
6.2,6.3, Table 1 & 4 (Joint Thickmess) |
- |
|
|
|
8 (Coating Test) |
- |
|
|
|
|
Partial
|
|
- |
Since the composition of cast iron shall be left to the discretion ofthe manufacturer , as such element to be tested with specified requirement and tolerances if any may please be declared with method of testing. Sample Size 5 pcs of 5x5 cm having dia> 3mm and thickness > 0.8 mm.;
EXCLUDING -; hydraulic test |
395 |
IS 14494 (2019) |
Elastomer insulated flexible cables for use in mines - Specification (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (CONDUCTOR) |
- |
|
|
|
5 (INSULATION) |
- |
|
|
|
5.1 (Power Cores) |
- |
|
|
|
5.2 (Pilot and Earth Cores) |
- |
|
|
|
7.1 (TAPE : Proofed Tape) |
- |
|
|
|
7.2 (TAPE : Polyethylene Terephalate (PETP) or
Polypropylene Base Tape) |
- |
|
|
|
7.3 (TAPE ) |
- |
|
|
|
8 (CENTRE) |
- |
|
|
|
9.1 (FILLERS) |
- |
|
|
|
9.2 (FILLERS) |
- |
|
|
|
10 (CRADLE SEPARATOR) |
- |
|
|
|
11.1 (ARMOUR) |
- |
|
|
|
11.2 a) (ARMOURING: Tensile Strength) |
- |
|
|
|
11.2 b) (ARMOURING: Elongation ) |
- |
|
|
|
11.2 c) (ARMOURING: Torsion Test (For round wire ) ) |
- |
|
|
|
11.2 d) (ARMOURING: Uniformity of zinc coating) |
- |
|
|
|
11.2 e) (ARMOURING: Mass of zinc coating ) |
- |
|
|
|
12.1 (SHEATH : Inner Sheath) |
- |
|
|
|
12.2 (SHEATH : Outer Sheath) |
- |
|
|
|
13.1 (REINFORCEMENT MATERIAL : Tape) |
- |
|
|
|
14.1 (CONSTRUCTION : CONDUCTOR) |
- |
|
|
|
14.2 (CONSTRUCTION : CONDUCTOR) |
- |
|
|
|
14.3 (CONSTRUCTION : CONDUCTOR) |
- |
|
|
|
16.1 (INSULATION) |
- |
|
|
|
16.2 (INSULATION : Thickness of Insulation) |
- |
|
|
|
16.3 (INSULATION : Tolerance on Insulation Thickness) |
- |
|
|
|
16.4 (INSULATION : Application of Insulation) |
- |
|
|
|
16.5 (INSULATION) |
- |
|
|
|
18 (PROTECTIVE SCREEN) |
- |
|
|
|
19 (CONDUCTANCE OF SCREEN) |
- |
|
|
|
19.1 (Individual Core Screen) |
- |
|
|
|
19.2 (Collective Screen) |
- |
|
|
|
20.1 (CORE IDENTIFICATION) |
- |
|
|
|
20.2 (Colour Scheme for Identification) |
- |
|
|
|
20.3 (Scheme for Identification by Numbering) |
- |
|
|
|
21.1 (LAYING UP OF CORES) |
- |
|
|
|
21.2 (LAYING UP OF CORES) |
- |
|
|
|
21.3 (LAYING UP OF CORES) |
- |
|
|
|
21.4 (LAYING UP OF CORES) |
- |
|
|
|
22.1 (INNER SHEATH) |
- |
|
|
|
22.2 (Thickness of Inner Sheath) |
- |
|
|
|
22.3 (INNER SHEATH) |
- |
|
|
|
23.1 (ARMOURING) |
- |
|
|
|
23.2 (ARMOURING) |
- |
|
|
|
23.3 (ARMOURING) |
- |
|
|
|
23.4 (ARMOURING) |
- |
|
|
|
24.1 (OUTER SHEATH) |
- |
|
|
|
24.2 (Thickness of Outer Sheath) |
- |
|
|
|
24.3 (Tolerance on Thickness of Outer Sheath) |
- |
|
|
|
24.4 (OUTER SHEATH) |
- |
|
|
|
25.1 (CABLE CONSTRUCTION AND DIMENSIONS) |
- |
|
|
|
27.8 (Flammability Test) |
- |
|
|
|
|
Partial
|
|
- |
EXCLUDING Ozone resistance test, dielectric pf test, Water Absorption Test, Heating cycle and partial discharge Test, High Voltage; |
396 |
IS 14845 (2000) |
Resilient seated cast iron air relief valves for water works purposes - specification |
- |
-
|
- View breakup
Rs 4660/- + charges as per relevant ISS excluding Function and performance test, High pressure orifice seat test and Low pressure orifice seat test
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
(Cl 3)&(Cl5) (Type & Nom Size) |
- |
|
|
|
(Cl 3)&(Cl5) (Type & Nom Size) |
- |
|
|
|
(Cl 3)&(Cl5) (Type & Nom Size) |
- |
|
|
|
(Cl 4) (Nom.Pressures) |
- |
|
|
|
(Cl 8) (End Connection) |
- |
|
|
|
(Cl.14) (Coating) |
- |
|
|
|
(Cl10.6) (Nut & Bolts) |
- |
|
|
|
(Cl.11) (Finish) |
- |
|
|
|
|
Partial
|
|
- |
Since the composition of cast iron shall be left to the discretion ofthe manufacturer , as such element to be tested with specified requirement and tolerances if any may please be declared with method of testing. Sample Size 5 pcs of 5x5 cm having dia> 3mm and thickness > 0.8 mm.;
EXCLUDING all except IS 318 : 1974, IS 320 : 1980; End Connection (Cl.8) for screwed connection, (Cl.12 )Testing and performance, |
397 |
IS 7142 (1995) |
Welded low carbon steel cylinders for low pressure liquifiable gases not exceeding 5 litre water capacity - Specification (First Revision) |
- |
-
|
Rs. 9552/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13 (CHECKING OF WATER CAPACITY) |
- |
|
|
|
14.1.1 (PROOF TEST) |
- |
|
|
|
15.1 (PNEUMATIC LEAKAGE TEST) |
- |
|
|
|
16.2 ( Bursting Test) |
- |
|
|
|
17.3 i) (Acceptance test Parent Metal Longitudinal test specimen;) |
- |
|
|
|
17.3 ii) (Acceptance test Parent Metal Longitudinal test specimen;) |
- |
|
|
|
17.3 iii) (Acceptance test Parent Metal Longitudinal test specimen;) |
- |
|
|
|
17.3 iv) (Acceptance test Parent Metal Circumferential test specimen;) |
- |
|
|
|
17.3 v) (Acceptance test Parent Metal Circumferential test specimen;) |
- |
|
|
|
17.3 vi) (Acceptance test Parent Metal Circumferential test specimen;) |
- |
|
|
|
17.3 vii) (Acceptance test Weld joint test Specimen) |
- |
|
|
|
17.4 (Bend test across weld) |
- |
|
|
|
17.5 (Macro-examination) |
- |
|
|
|
17.6 (Minimum Thickness Test) |
- |
|
|
|
10.3 (Bung) |
- |
|
|
|
10.1 (FITTINGS OTHER THAN VALVES) |
- |
|
|
|
10.2 ii) (FITTINGS OTHER THAN VALVES) |
- |
|
|
|
10.2 iii) (FITTINGS OTHER THAN VALVES) |
- |
|
|
|
19 (COLOUR IDENTIFICATION) |
- |
|
|
|
9.1 (VALVES AND VALVES PAD) |
- |
|
|
|
|
Partial
|
|
- |
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
EXCLUDING "-; 16.1 Hydrostatic Stretch Test 10.3 Bung" |
398 |
IS 15905 (2011) |
Hubless centrifugally cast (Spun) iron pipes, fittings and accessories - Spigot series - Specification |
- |
-
|
Rs. 5745/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.3 (Hardness ) |
- |
|
|
|
7.1 (Visual Inspection and Hammer Test) |
- |
|
|
|
8.1 (Crushing Strength ) |
- |
|
|
|
9.1 (Hydraustatic Test) |
- |
|
|
|
10.1 (External Diameter) |
- |
|
|
|
10.2, Table 3, Sl no. I to IV (Pipe Thickness) |
- |
|
|
|
10.2 , Table 3, Sl no. I to IV (Fittings Thickness) |
- |
|
|
|
10.3 (Length) |
- |
|
|
|
10.5 (Masses) |
- |
|
|
|
11.2.1, 11.2.2, Table 4 and 5, Sl no. Ito V (Nominal Size (DN)) |
- |
|
|
|
11.2.1, 11.2.2, Table 4 and 5, Sl no. I to V (a) |
- |
|
|
|
11.2.3, Table 6, Sl no. I to IV (Nominal Size (DN 1)) |
- |
|
|
|
11.2.3, Table 6, Sl no. I to IV (a) |
- |
|
|
|
11.2.3, Table 6, Sl no. I to IV (r) |
- |
|
|
|
11.2.4, Table 7, Sl no. I to V (Nominal Size (DN 1)) |
- |
|
|
|
11.2.4, Table 7, Sl no. I to V (a) |
- |
|
|
|
11.2.4, Table 7, Sl no. I to V (b) |
- |
|
|
|
11.2.5, Table 8, Sl no. I to II (Nominal Size (DN 1)) |
- |
|
|
|
11.2.5, Table 8, Sl no. I to II (Nominal Size (DN 2)) |
- |
|
|
|
11.2.5, Table 8, Sl no. I to II (a) |
- |
|
|
|
11.2.5, Table 8, Sl no. I to II (r) |
- |
|
|
|
11.2.5, Table 8, Sl no. I to II (b) |
- |
|
|
|
11.2.5, Table 8, Sl no. I to II (c ) |
- |
|
|
|
11.2.5, Table 8, Sl no. I to II (d) |
- |
|
|
|
11.2.6, Table 9, Sl no. I to II (Nominal Size (DN )) |
- |
|
|
|
11.2.6, Table 9, Sl no. I to II (a) |
- |
|
|
|
11.2.6, Table 9, Sl no. I to II (b) |
- |
|
|
|
11.2.6, Table 9, Sl no. I to II (c) |
- |
|
|
|
11.2.6, Table 9, Sl no. I to II (r) |
- |
|
|
|
11.2.7, 11.2.8, 11.2.9, 11.2.10 Table 10,11,12 & 13 (Nominal Size (DN 1)) |
- |
|
|
|
11.2.7, 11.2.8, 11.2.9, 11.2.10 Table 10,11,12 & 13 (Nominal Size (DN 2)) |
- |
|
|
|
11.2.7, 11.2.8, 11.2.9, 11.2.10 Table 10,11,12 & 13 (L) |
- |
|
|
|
11.2.7, 11.2.8, 11.2.9, 11.2.10 Table 10,11,12 & 13 (a) |
- |
|
|
|
11.2.7, 11.2.8, 11.2.9, 11.2.10 Table 10,11,12 & 13 (b) |
- |
|
|
|
11.2.11, Table 14, (Nominal Size (DN 1)) |
- |
|
|
|
11.2.11, Table 14, (Nominal Size (DN 2)) |
- |
|
|
|
11.2.11, Table 14, ( L) |
- |
|
|
|
11.2.12, Table 15 (Nominal Size (DN )) |
- |
|
|
|
11.2.12, Table 15 (L) |
- |
|
|
|
11.2.12, Table 15 (a) |
- |
|
|
|
5.1 (shall conform to FG 150 grade,appropriate, specified in IS 210.) |
- |
|
|
|
|
Partial
|
|
- |
Since the composition of cast iron shall be left to the discretion ofthe manufacturer , as such element to be tested with specified requirement and tolerances if any may please be declared with method of testing. Sample Size 5 pcs of 5x5 cm having dia> 3mm and thickness > 0.8 mm.;
EXCLUDING -; hydraulic test |
399 |
IS 444 (2017) |
Rubber hoses, textile - Reinforced, for general - Purpose water applications - Specification (Fifth Revision) |
- |
-
|
- View breakup
Testing Charges for the product as per 444:2017/ISO 1403:2005 = 8250
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (Classification - IS 444) |
- |
|
|
|
5 (Lining - IS 444) |
- |
|
|
|
5 (Reinforcement - IS 444) |
- |
|
|
|
5 (Lining and Cover - IS 444) |
- |
|
|
|
6.1- Table 1 (Internal diameters - ISO 4671) |
- |
|
|
|
6.2 (Concentricity - ISO 4671) |
- |
|
|
|
6.3 (Length -IS 4671) |
- |
|
|
|
6.4 ( thickness of the lining plus cover - ISO 4671) |
- |
|
|
|
6.4 (If the cover is fluted, the depth of the flutes - ISO 4671) |
- |
|
|
|
7.1 - Table 2 ( tensile strength of Lining - ISO 37 ) |
- |
|
|
|
7.1 - Table 2 ( tensile strength of Cover - ISO 37 ) |
- |
|
|
|
7.1 - Table 2 (elongation at break of Lining - ISO 37) |
- |
|
|
|
7.1 - Table 2 (elongation at break of Cover - ISO 37) |
- |
|
|
|
7.1 - Table 2 (Change in tensile strength of Lining from original value after ageing(max) - ISO 188 and ISO 37) |
- |
|
|
|
7.1 - Table 2 (Change in tensile strength of Cover from original value after ageing(max) - ISO 188 and ISO 37) |
- |
|
|
|
7.1 - Table 2 (Change in elongation at break of Lining from original value after ageing (max.) - ISO 188 and ISO 37) |
- |
|
|
|
7.1 - Table 2 (Change in elongation at break of Cover from original value after ageing (max.) - ISO 188 and ISO 37) |
- |
|
|
|
7.2 - Table 3 (Proof pressure at 23 °C - ISO 1402) |
- |
|
|
|
7.2 - Table 3 (Change in length at proof pressure - ISO 1402) |
- |
|
|
|
7.2 - Table 3 (Minimum burst pressure - ISO 1402) |
- |
|
|
|
7.2 - Table 3 (Flexibility at 23 °C - Method A of ISO 1746) |
- |
|
|
|
7.2 - Table 3 (Low-temperature flexibility - Method B of ISO 4672) |
- |
|
|
|
|
Partial
|
|
- |
Excluding -; Test facility not available For Resistance to liquids, Burst test, Adhesion test, Ozone Test, Flexibility test |
400 |
IS 12701 (1996) |
Rotational moulded polyethylene water storage tanks - specification (First Revision) |
- |
-
|
- View breakup
Rs. 9385/- + Material Testing charges as per relevant referred ISs
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 Table 1 (Dimensioas of Cylinderical Vertical Tank) |
- |
|
|
|
|
Partial
|
|
- |
Complete for Chemical, Total Surface Area in cm2 to be declared on Test request;
Excluding : Available up to 2000 L capacity except for Flexural Modulus (Cl. 7.5); |
401 |
IS 1626 : Part 3 (1994) |
Asbestos Cement Building types and Pipe Fittings, Gutters and Gutter Fittings and Roofing Fittings - Part 3 : Roofing Fittings |
- |
-
|
Rs.3300.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2 (Dimensions) |
- |
|
|
|
7 (Genaral appearance and finish) |
- |
|
|
|
6.1 (Physical requirements) |
- |
|
|
|
6.2 (Impermeability test according to the Method 1 described in IS 5913 : 1989) |
- |
|
|
|
|
Partial
|
|
- |
- |
402 |
IS 15354 : Part 1 (2018) |
Single - Use medical examination gloves: Part 1 specification for gloves made from rubber latex or rubber solution (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 & Table 2 (Size code) |
- |
|
|
|
6.1 & Table 2 (Width corresponding to size code (dimension w,Figure 1)) |
- |
|
|
|
6.1 & Table 2 (Descriptive size) |
- |
|
|
|
6.1 & Table 2 (Width corresponding to Descriptive size (dimension w,Figure 1)) |
- |
|
|
|
6.1 & Table 2 (Minimum length (dimension l,
Figure 1)) |
- |
|
|
|
6.1 & Table 2 (Minimum thickness (at locations
shown in Figure 2)) |
- |
|
|
|
6.1 & Table 2 (Maximum thickness
(at approximate
centre of palm)) |
- |
|
|
|
6.2 (Watertightness) |
- |
|
|
|
6.3.2 & Table 3 (Minimum force at break before accelerated ageing) |
- |
|
|
|
6.3.2 & Table 3 (Minimum Elongation at break before accelerated ageing) |
- |
|
|
|
6.3.3 & Table 3 (Minimum force at break after accelerated ageing) |
- |
|
|
|
6.3.3 & Table 3 (Minimum Elongation at break after accelerated ageing) |
- |
|
|
|
|
Partial
|
|
- |
- |
403 |
IS 5312 : Part 1 (2004) |
Swing Check Type Reflux (Non-Return] Valves for Water Works Purposes - Part 1 : Single-Door Pattern |
- |
-
|
Rs 5700/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3 (Nominal Pressure) |
- |
|
|
|
4 (Nominal Sizes) |
- |
|
|
|
4.1.1 (Actual bore) |
- |
|
|
|
6.2 (Manufacture Dimensions Table 2 ) |
- |
|
|
|
6.2 (Manufacture Dimensions Table 2 ) |
- |
|
|
|
6.4 (Manufacture ) |
- |
|
|
|
6.5 (Manufacture ) |
- |
|
|
|
6.5 (Manufacture ) |
- |
|
|
|
6.7 (Manufacture ) |
- |
|
|
|
6.8 (Manufacture ) |
- |
|
|
|
6.9 (Manufacture ) |
- |
|
|
|
6.9 (Manufacture ) |
- |
|
|
|
6.9 (Manufacture ) |
- |
|
|
|
6.10 (Manufacture ) |
- |
|
|
|
6.10.1 (Manufacture ) |
- |
|
|
|
6.12 (Door Faces) |
- |
|
|
|
6.13 (By-pass arrangements) |
- |
|
|
|
6.13.1 (By-pass arrangements) |
- |
|
|
|
6.13.1 (By-pass arrangements) |
- |
|
|
|
8.2 (Hydrostatic Body Test ) |
- |
|
|
|
8.3 (Hydrostatic Seat Test) |
- |
|
|
|
|
Partial
|
|
- |
-; Complete(up to 200 mm nominal size) |
404 |
IS 12330 (1988) |
Specificatioon for sulphate resisting Portland cement |
- |
-
|
Rs.12900/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 (Fineness 4031 Part 2) |
- |
|
|
|
5.2.1 (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
5.2.1 (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
5.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
5.3 b) (Setting Time Final- 4031 Part 5) |
- |
|
|
|
5.5 iii) (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
5.1 (Fineness 4031 Part 2) |
- |
|
|
|
5.2.1 (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
5.2.1 (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
5.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
5.3 b) (Setting Time Final- 4031 Part 5) |
- |
|
|
|
5.5 iii) (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
5.1 (Fineness 4031 Part 2) |
- |
|
|
|
5.2.1 (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
5.2.1 (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
5.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
5.3 b) (Setting Time Final- 4031 Part 5) |
- |
|
|
|
5.5 iii) (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
5.1 (Fineness 4031 Part 2) |
- |
|
|
|
5.2.1 (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
5.2.1 (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
5.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
5.3 b) (Setting Time Final- 4031 Part 5) |
- |
|
|
|
5.5 iii) (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
5.1 (Fineness 4031 Part 2) |
- |
|
|
|
5.2.1 (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
5.2.1 (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
5.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
5.3 b) (Setting Time Final- 4031 Part 5) |
- |
|
|
|
5.5 iii) (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
5.1 (Fineness 4031 Part 2) |
- |
|
|
|
5.2.1 (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
5.2.1 (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
5.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
5.3 b) (Setting Time Final- 4031 Part 5) |
- |
|
|
|
5.5 iii) (Compressive Strength At 672 hrs ± 4 hr - IS 4031 Part 6) |
- |
|
|
|
|
Partial
|
|
- |
complete for chemical;
Excluding: -; Salphate Espansion |
405 |
IS 9763 (2000) |
Plastics Bib Taps, Pillar Taps, Angle Valves and Stop Valves for Hot and Cold Water Services - |
- |
-
|
Rs.7800/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
(Cl. 5) (Nominal Size) |
- |
|
|
|
(Cl. 7) (Identification) |
- |
|
|
|
(Cl. 7) (Identification) |
- |
|
|
|
(Cl. 4) (Materials) |
- |
|
|
|
(Cl.6 , Table 3) (Dimensions) |
- |
|
|
|
(Cl 8) (Construction,Workmanship and Finish) |
- |
|
|
|
(Cl 8) (Construction,Workmanship and Finish) |
- |
|
|
|
(Cl 8) (Construction,Workmanship and Finish) |
- |
|
|
|
(Cl 8.4) (Minimum Thickness) |
- |
|
|
|
(Cl. 8.5) (Finish) |
- |
|
|
|
(Cl 9.2) (Drip Proofness Test) |
- |
|
|
|
(Cl 9.3) (Thermal Shock Test ) |
- |
|
|
|
(Cl 9.4) (Hydraulic Pressure Test) |
- |
|
|
|
(Cl 9.5) (Mechanical Strength Characteristics) |
- |
|
|
|
|
Partial
|
|
- |
- |
406 |
IS 9857 (1990) |
Welding cables - Specification (First Revision) |
- |
-
|
Rs 11400/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (Conductor : Material ) |
- |
|
|
|
5 (SEPARATOR) |
- |
|
|
|
6 (COVERING) |
- |
|
|
|
7 (CONDUCTOR : CONSTRUCTION ) |
- |
|
|
|
8 (S E P A R A T O R) |
- |
|
|
|
9.1 (C O V E R I N G : Application ) |
- |
|
|
|
9.2 (T h i c k n e s s o f C o v e r i n g) |
- |
|
|
|
9.3 (T o l e r a n c e on Thickness o f C o v e r i n g) |
- |
|
|
|
9.4 (A p p l i c a t i o n of C o v e r i n g) |
- |
|
|
|
9.5 (Colour of C o v e r i n g) |
- |
|
|
|
10.1 a) 1) (Annealing test - IS 10810: Part 1) |
- |
|
|
|
10.1 a) 2) (Conductor resistance tes - IS 10810 : Part 5) |
- |
|
|
|
10.1 c) 1) (Physical tests for
covering : Tensile strength ) |
- |
|
|
|
10.1 c) 1) (Physical tests for
covering : Elongation at break ) |
- |
|
|
|
10.1 c) 2) (Physical tests for
covering - Ageing in Air oven : Tensile strength variation) |
- |
|
|
|
10.1 c) 2) (Physical tests for
covering -Ageing in Air oven : Elongation variation at break ) |
- |
|
|
|
10.1 c) 3) (Physical tests for
covering - Ageing in Air Bomb : Tensile strength variation ) |
- |
|
|
|
10.1 c) 3) (Physical tests for
covering -Ageing in Air Bomb : Elongation variation at break ) |
- |
|
|
|
10.1 c) 4) (Physical tests for
covering - Oil Resistance : Tensile strength variation ) |
- |
|
|
|
10.1 c) 4) (Physical tests for
covering - Oil Resistance : Elongation variation at break ) |
- |
|
|
|
10.1 c) 5) (Hot set test ) |
- |
|
|
|
10.1 c) 5) (Permanent set ) |
- |
|
|
|
11.1 (High Voltage Test ( Water Immersion
Test )) |
- |
|
|
|
11.3 (Static Flexibility Test) |
- |
|
|
|
11.4 (Flammability Test) |
- |
|
|
|
12.1 (Manufacturer's Identification) |
- |
|
|
|
12.2 (Cable Identification) |
- |
|
|
|
12.3 (Cable Code) |
- |
|
|
|
13.1 (Packing ) |
- |
|
|
|
13.2 (Marking) |
- |
|
|
|
7 (CONDUCTOR : CONSTRUCTION ) |
- |
|
|
|
|
Partial
|
|
- |
- |
407 |
IS 9758 (1981) |
Specification for flush valves and fittings for water closets and urinals |
- |
-
|
Rs. 1950/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
cl 5 (Manufacture & Construction) |
- |
|
|
|
cl 6.1 to 6.3 (Performance requirements) |
- |
|
|
|
cl 7.1 (Hydraulic pressure test) |
- |
|
|
|
cl 8 (Finish) |
- |
|
|
|
|
Complete
|
|
- |
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
Excluding: Complete for Material; |
408 |
IS 1364 : Part 1 (2018) |
Hexagon head bolts, screws and nuts of product grades A and B: Part 1 hexagon head bolts (Size Range M 1.6 To M 64) (Fifth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3 (Dimensions- d) |
- |
|
|
|
4-Table 3 (Machined test pc- Proof stress) |
- |
|
|
|
4-Table 3 (Machined test pc- Tensile Strength) |
- |
|
|
|
4-Table 3 (Machined test pc- Elongation) |
- |
|
|
|
4-Table 3 (Full size bolts- Ultimate tensile strength) |
- |
|
|
|
4-Table 3 (Proof load test) |
- |
|
|
|
4-Table 3 (Surface Integrity Test ) |
- |
|
|
|
|
Partial
|
|
- |
Excluding: -; cl4 &Table 3 except hardness test |
409 |
IS 9396 : Part 1 (1987) |
Specification for round open top sanitary cans for foods and drinks: Part 1 tinplate (First Revision) |
- |
-
|
Rs. 6883/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.2 (Tinplate Thickness and
Dimension : Thickness) |
- |
|
|
|
3.2 (Tinplate Thickness and
Dimension : Feather Edge: the thickness when measured at a distance of 10 mm from the mill trimmed edge shall not deviate from the actual centre thickness by more than −6 %) |
- |
|
|
|
3.2 (Tinplate Thickness and
Dimension: width) |
- |
|
|
|
3.2 (Tinplate Thickness and
Dimension : length) |
- |
|
|
|
3.2 (Tinplate Thickness and
Dimension : Edge camber) |
- |
|
|
|
3.2 (Tinplate Thickness and
Dimension :Out of squareness of sheet ) |
- |
|
|
|
3.2 (Tinplate Thickness and
Dimension : Flatness) |
- |
|
|
|
|
Partial
|
|
- |
- |
410 |
IS 1363 : Part 3 (2018) |
Hexagon Head Bolts, Screws and Nuts of Product Grade ËœC â„¢ Part 3 (Style 1) Hexagon Nuts ( Size Range M 5 to M 64 ) ( Fifth Revision ) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3-Table 1 (Dimensions-D) |
- |
|
|
|
3-Table 1 (Dimensions-P) |
- |
|
|
|
3-Table 1 (Dimensions-dw(minimum)) |
- |
|
|
|
3-Table 1 (Dimensions-e(minimum)) |
- |
|
|
|
3-Table 2 (Dimensions-m(minimum)) |
- |
|
|
|
3-Table 1 (Dimensions-m(maximum)) |
- |
|
|
|
3-Table 1 (Dimensions-mw(minimum)) |
- |
|
|
|
3-Table 1 (Dimensions-s(minimum)) |
- |
|
|
|
3-Table 1 (Dimensions-s(maximum)) |
- |
|
|
|
3-Table 2 (Dimensions-D) |
- |
|
|
|
3-Table 2 (Dimensions-P) |
- |
|
|
|
3-Table 2 (Dimensions-dw(minimum)) |
- |
|
|
|
3-Table 2 (Dimensions-e(minimum)) |
- |
|
|
|
3-Table 2 (Dimensions-m(minimum)) |
- |
|
|
|
3-Table 2 (Dimensions-m(maximum)) |
- |
|
|
|
3-Table 1 (Dimensions-mw(minimum)) |
- |
|
|
|
3-Table 2 (Dimensions-s(minimum)) |
- |
|
|
|
3-Table 2 (Dimensions-s(maximum)) |
- |
|
|
|
4-Table 3 (General requirements) |
- |
|
|
|
|
Partial
|
|
- |
Excluding : -; cl4 &Table 3 except hardness test |
411 |
IS 13098 (2012) |
Automotive vehicles - Tubes for pneumatic tyres - Specification (First Revision) |
- |
-
|
Total Resting Charges : Rs. 13,050.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3/3.1 (for valve refer IS 9081) (MATERIALS, FORM AND FIT) |
- |
|
|
|
3/3.3 (Uniformity(The Thickness shall not vary from the arithmetic mean of the readings by ± 17.5 % at any point in longitudinal direction :-Crown centre,Base centre,Side wall - 1,Side wall - 2)) |
- |
|
|
|
4/4.1.1 (Elongation at break (Class A' Tubes)) |
- |
|
|
|
4/4.1.1 (Elongation at break (Class B' Tubes)) |
- |
|
|
|
4/4.1.2 ( Strength of Splice (Class A' Tubes)) |
- |
|
|
|
4/4.1.2 ( Strength of Splice (Class B' Tubes)) |
- |
|
|
|
4/4.1.3 Refer annex B (Set After Ageing(Class A' Tubes)) |
- |
|
|
|
4/4.1.3 Refer annex B (Set After Ageing(Class B' Tubes)) |
- |
|
|
|
4/4.1.4 Refer annex C (Accelerated Ageing(Both Class A and Class B)) |
- |
|
|
|
5 (AIR TIGHTNESS) |
- |
|
|
|
|
Partial
|
|
- |
- |
412 |
IS 8329 (2000) |
Centrifugally cast (Spun) ductile iron pressure pipes for water, gas and sewage - Specification (Third Revision) |
- |
-
|
Rs.7800/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 10 (Hardness & Tensile Test) |
- |
|
|
|
Cl 13 (Length, Diameter, Wall Thickness & Ovality) |
- |
|
|
|
|
Partial
|
|
- |
Excluding : -; hydrulic test for unflanged pipe |
413 |
IS 10701 (2012) |
Structural plywood - Specification (First Revision) |
- |
-
|
- View breakup
Rs.9600.00 + charges for as per referred ISs.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
11.4.1 (Resistance to Water) |
- |
|
|
|
11.4.2 (Resistance to Water) |
- |
|
|
|
11.6 (Tensile Strength) |
- |
|
|
|
11.7.1 (Compressive Strength, Bending Strength, Panel Shear Strength, Plate Shear Strength and Rolling Shear Strngth) |
- |
|
|
|
11.8 (Wet Bending Strength) |
- |
|
|
|
Clause 11.2 (Moisture content) |
- |
|
|
|
|
Partial
|
|
- |
Excluding : Test facility not available for Cl 11.7 Penals shear strength, Modulus of rigidity,Rolling shear strength cl.11.8 Static Bending Strength and Wet Bending Strength Above 15 mm thickness
sample size required:A) Structural Plywood – 2 Sheets B) Face And Core Veneers, Cross-Bands – 2 Sheets Of Suitable Size
Sample Size without dimensional measurements: Length-1800 mm, width-1200 |
414 |
IS 784 (2019) |
Prestressed concrete pipes (Including Specials) - Specification (Third Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5&5.1 table 1,i (Nominal Internal Diameter of Pipe) |
- |
|
|
|
5&5.1 table 1,ii (Minimum Core Thickness) |
- |
|
|
|
5.2 (Length) |
- |
|
|
|
5.3.2 (Internal Diameter) |
- |
|
|
|
|
Partial
|
|
- |
- |
415 |
IS 8035 (1999) |
Handpump - Shallow well - Specification (First Revision) |
- |
-
|
Rs. 8850/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 (Visual Tests) |
- |
|
|
|
6.2 (Dimensional and Other Tests) |
- |
|
|
|
6.2.2 (Dimensional and Other Tests) |
- |
|
|
|
6.2.3 (Dimensional and Other Tests) |
- |
|
|
|
|
Partial
|
|
- |
- |
416 |
IS 4003 : Part 1 (1978) |
Specification for pipe wrenches: Part 1 general purpose (First Revision) |
- |
-
|
Rs. 3600/- and testing charges as per referred Iss View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3 (Dimensions- Nominal Size) |
- |
|
|
|
3 (Dimensions-Minimum capacity) |
- |
|
|
|
3 (Dimensions-Maximum capacity, D) |
- |
|
|
|
3 (Dimensions- Jaw Thickness,T min) |
- |
|
|
|
3 (Dimensions- Length of movablejae, l1) |
- |
|
|
|
3 (Dimensions- Length of Handle, l2) |
- |
|
|
|
3 (Dimensions- Width of Nut, N) |
- |
|
|
|
5 (Hardness- Jaws) |
- |
|
|
|
5 (Hardness- Handle of movable Jaw) |
- |
|
|
|
5 (Hardness- Shank of movable Jaw) |
- |
|
|
|
6.1 (Manufacture- Handel) |
- |
|
|
|
6.1 (Manufacture- Handel) |
- |
|
|
|
6.2 (Manufacture- Movable Jaw) |
- |
|
|
|
6.2 (Manufacture- Movable Jaw) |
- |
|
|
|
6.2 (Manufacture- Movable Jaw) |
- |
|
|
|
6.3 (Manufacture- Adjusting Nut) |
- |
|
|
|
6.3 (Manufacture- Adjusting Nut) |
- |
|
|
|
6.4 (Manufacture- Frame) |
- |
|
|
|
6.5 (Manufacture- Hinge Pin) |
- |
|
|
|
6.6 (Manufacture- Spring) |
- |
|
|
|
6.6 (Manufacture- Spring) |
- |
|
|
|
6.6 (Manufacture- Spring) |
- |
|
|
|
7 (Workmanship & Finish) |
- |
|
|
|
7 (Workmanship & Finish) |
- |
|
|
|
7 (Workmanship & Finish) |
- |
|
|
|
8 (Operation) |
- |
|
|
|
8 (Operation) |
- |
|
|
|
|
Complete
|
|
- |
Sample size shall be minimum dia> 3mm and thickness > 0.8 mm;
Excluding : Complete for Component material; |
417 |
IS 650 (1991) |
Standard sand for testing cement - Specification (Second Revision) |
- |
-
|
Rs 1500.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 4.1 (shall be of quartz, light grey or whitish variety and shall be free from silt. The sand grains shall be angular, the shape of the grains approximating to the spherical form; elongated and flattened grains being present only in very small or negligible quantities) |
- |
|
|
|
Cl. 4.2 (Sieve test and particle size distribution) |
- |
|
|
|
|
Complete
|
|
- |
complete for chemical; |
418 |
IS 9968 : Part 2 (2002) |
Specification for elastomer - Insulated cables: Part 2 for working voltages from 3.3 kV up to and including 33 kV (First Revision) |
- |
-
|
Rs. 14450/ View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (CONDUCTORS: Cables for Fixed Installation) |
- |
|
|
|
4.2 (CONDUCTORS:Flexible Cables) |
- |
|
|
|
5 (INSULATION) |
- |
|
|
|
7.1 (Proofed Tape) |
- |
|
|
|
7.2 (Polyethylene Terephthalate ( P E T P ) or
Polypropylene Base Tape : Thickness) |
- |
|
|
|
8 (SCREENING) |
- |
|
|
|
9 (CENTRE AND FILLERS) |
- |
|
|
|
10 (ARMOUR) |
- |
|
|
|
11.1 (Inner Sheath) |
- |
|
|
|
11.2 (Outer Sheath) |
- |
|
|
|
12.1 (Tapes) |
- |
|
|
|
13.1 & 13.2 (CONSTRUCTION:CONDUCTORS-Cables for Fixed Installations/Flexible Cables) |
- |
|
|
|
13.3 (Earthing Conductor) |
- |
|
|
|
13.3.1 (Earthing Conductor) |
- |
|
|
|
13.4 (Separator Tape) |
- |
|
|
|
14 (CONDUCTOR SCREENING) |
- |
|
|
|
15.1 (INSULATION : Application) |
- |
|
|
|
15.2 (Thickness of Insulation) |
- |
|
|
|
15.3 (Tolerance on Thickness of Insulation) |
- |
|
|
|
16.1 (INSULATION SCREENING : Application) |
- |
|
|
|
16.2 (INSULATION SCREENING : Parts ) |
- |
|
|
|
16.3 (INSULATION SCREENING : Non Metallic Parts ) |
- |
|
|
|
16.4 (INSULATION SCREENING : Metallic Parts ) |
- |
|
|
|
17 (CORE IDENTIFICATION) |
- |
|
|
|
17 (CORE IDENTIFICATION: Unscreed cable ) |
- |
|
|
|
18.1 (LAYING UP OF CORES) |
- |
|
|
|
18.2 (LAYING UP OF CORES : Flexible cable) |
- |
|
|
|
18.3 (LAYING UP OF CORES : Binder Tape) |
- |
|
|
|
19.1 (Inner Sheath : Application) |
- |
|
|
|
19.2 (Thickness of Inner Sheath) |
- |
|
|
|
19.3 (Inner Sheath : proofed tape) |
- |
|
|
|
20.1 (ARMOURING: Application) |
- |
|
|
|
20.2 (Type of Armour) |
- |
|
|
|
20.2 1.2 (Direction of lay of armour) |
- |
|
|
|
20.2 1.3 (Joint in armour) |
- |
|
|
|
21.1 (OUTER SHEATH) |
- |
|
|
|
21.2 (Coulor of Outer sheath) |
- |
|
|
|
21.3 (Thickness of Outer Sheat: Average) |
- |
|
|
|
21.3 (Thickness of Outer Sheat: Minimum) |
- |
|
|
|
22.1 a)1) (Annealing test
(for copper) - IS 10810: Part 1) |
- |
|
|
|
22.1 a)2) (Tensile test
(for aluminium) -IS 10810: Part 2) |
- |
|
|
|
22.1 a)3) (Wrapping Test
(for aluminium) - IS 10810: Part 3) |
- |
|
|
|
22.1 a)4) (Conductor resistance
test) |
- |
|
|
|
22.1 a)5) (Persulphate test
(tinned copper
conductor)- IS 10810: Part 4) |
- |
|
|
|
4.1 (CONDUCTORS: Cables for Fixed Installation) |
- |
|
|
|
4.2 (CONDUCTORS:Flexible Cables) |
- |
|
|
|
4.1 (CONDUCTORS: Cables for Fixed Installation) |
- |
|
|
|
4.2 (CONDUCTORS:Flexible Cables) |
- |
|
|
|
22.1 b)2)i) (Test for Galvanized Steel
Wires/Formed Wires
2) Tensile Strentgh -IS 10810: Part 37) |
- |
|
|
|
22.1 b)2)ii) (Test for Galvanized Steel
Wires/Formed Wires
2) Elongation at break -IS 10810: Part 37) |
- |
|
|
|
22.1 b)2)iii) (Test for Galvanized Steel
Wires/Formed Wires
3) Torsion (for round
wires only) -IS 10810: Part 38) |
- |
|
|
|
22.1 b)2)iv) (Test for Galvanized Steel
Wires/Formed Wires
4) Winding (for strips
only) -IS 10810: Part 39) |
- |
|
|
|
22.1 b)2)v) (Test for Galvanized Steel
Wires/Formed Wires
5) Zinc coating : Uniformity-IS 10810: Part 40) |
- |
|
|
|
22.1 b)2)vi) (Test for Galvanized Steel
Wires/Formed Wires
5) Zinc coating : Mass -IS 10810: Part 41) |
- |
|
|
|
22.1 b)2) vii) (Resistivity - IS 10810: Part 42) |
- |
|
|
|
22.1 c)2) (Physical Tests for
Insulation : Tensile Strenth - IS 10810: Part 7) |
- |
|
|
|
22.1 c)2) (Physical Tests for
Insulation : Elongation - IS 10810: Part 7) |
- |
|
|
|
22.1 c)3) (Physical Tests for
Insulation ( Ageing in air oven): Tensile Strenth - IS 10810: Part 11) |
- |
|
|
|
22.1 c)3) (Physical Tests for
Insulation ( Ageing in air oven): Tensile Strenth Variation - IS 10810: Part 12) |
- |
|
|
|
22.1 c)3) (Physical Tests for
Insulation( Ageing in air oven) : Elongation - IS 10810: Part 11) |
- |
|
|
|
22.1 c)3) (Physical Tests for
Insulation( Ageing in air oven) : Elongation variation - IS 10810: Part 12) |
- |
|
|
|
22.1 c)4) (Physical Tests for
Insulation ( Ageing in air bomb): Tensile Strenth variation - IS 10810: Part 56) |
- |
|
|
|
22.1 c)5) (Physical Tests for
Insulation :Hot set Elongation - IS 10810: Part 30) |
- |
|
|
|
22.1 c)5) (Physical Tests for
Insulation :Permanent set - IS 10810: Part 30) |
- |
|
|
|
22.1 c)2) (Physical Tests for
Sheath : Tensile Strenth - IS 10810: Part 7) |
- |
|
|
|
22.1 c)2) (Physical Tests for
Sheath : Elongation - IS 10810: Part 7) |
- |
|
|
|
22.1 c)3) (Physical Tests for
Sheath( Ageing in air oven) : Tensile Strenth - IS 10810: Part 11) |
- |
|
|
|
22.1 c)3) (Physical Tests for
Insulation ( Ageing in air oven): Tensile Strenth Variation - IS 10810: Part 12) |
- |
|
|
|
22.1 c)3) (Physical Tests for
Sheath ( Ageing in air oven): Elongation - IS 10810: Part 11) |
- |
|
|
|
22.1 c)3) (Physical Tests for
Sheath ( Ageing in air oven): Elongation variation - IS 10810: Part 12) |
- |
|
|
|
22.1 c)10) (Loss of mass in air
oven : Sheath - IS 10810: Part 10) |
- |
|
|
|
22.1 c)6) (Physical Tests for
Sheath(Oil resistance test) : Tensile Strenth Variation - IS 10810: Part 31) |
- |
|
|
|
22.1 c)6) (Physical Tests for
Sheath ( Oil resistance test): Elongation Variation - IS 10810: Part 31) |
- |
|
|
|
22.1 c)7) (Tear Resistance test - IS 10810: Part 17) |
- |
|
|
|
22.1 c)5) (Physical Tests for
Sheath :Hot set Elongation - IS 10810: Part 30) |
- |
|
|
|
22.1 c)5) (Physical Tests for
Sheath :Permanent set - IS 10810: Part 30) |
- |
|
|
|
22.1 c)8) (Shrinkage test : Sheath - IS 10810: Part 12) |
- |
|
|
|
22.1 c)8) (Shrinkage test - Crack oberved : Sheath - IS 10810: Part 13) |
- |
|
|
|
22.1 c)9) (Hot deformation test : Sheath - IS 10810: Part 15) |
- |
|
|
|
22.1 c)11) (Heat shock : Sheath - IS 10810: Part 14) |
- |
|
|
|
22.1 c)12) (Thermal stability : Sheath - IS 10810: Part 60) |
- |
|
|
|
22.1 d) (Insulation Resistance Test: Volume resistivity ) |
- |
|
|
|
22.1 d) (Insulation Resistance Test: Insulation resistance constant ) |
- |
|
|
|
22.1 k) (High Voltage Test
for Four Hours) |
- |
|
|
|
22.1 n) (Flammability) |
- |
|
|
|
|
Partial
|
|
- |
EXCLUDING Water absorption test, partial discharge test, impulse test, dielectric pf test, heating cycle, and HV test; |
419 |
IS 7834 : Part 1 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 1 General requirements |
- |
-
|
Rs.2400/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.4 (Minimum Thickness) |
- |
|
|
|
Cl. 5.1.1, 5.1.2, Table 1, Fig 1 (Minimum Socket Length) |
- |
|
|
|
Cl. 6.1 (Stress Relief Test- Appendix A) |
- |
|
|
|
|
Partial
|
|
- |
EXCLUDING Test facility not available for Cl. 6.4 Short Term Hydraulic Test; |
420 |
IS 371 (1999) |
Ceiling roses - Specification (Third Revision) |
- |
-
|
Rs 5700/- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9 (Marking) |
- |
|
|
|
10.1 (Dimentions) |
- |
|
|
|
10.2 (Dimentions) |
- |
|
|
|
11.1 (Accessibility of live parts ) |
- |
|
|
|
11.2 (Accessibility of live parts ) |
- |
|
|
|
11.3 (Accessibility of live parts ) |
- |
|
|
|
11.4 (Accessibility of live parts ) |
- |
|
|
|
11.4.1 (Accessibility of live parts ) |
- |
|
|
|
12.1 (Provision for Earthing) |
- |
|
|
|
12.2 (Provision for Earthing) |
- |
|
|
|
13.1 (Terminals) |
- |
|
|
|
13.2 (Terminals) |
- |
|
|
|
13.3 (Terminals) |
- |
|
|
|
13.4 (Terminals) |
- |
|
|
|
13.5 (Terminals) |
- |
|
|
|
13.6 (Terminals) |
- |
|
|
|
13.7 (Terminals) |
- |
|
|
|
13.8.1 (Terminals) |
- |
|
|
|
13.8.2 (Terminals) |
- |
|
|
|
13.8.3 (Terminals) |
- |
|
|
|
14.1 (Construction) |
- |
|
|
|
14.2 (Construction) |
- |
|
|
|
14.3 (Construction) |
- |
|
|
|
14.4 (Construction) |
- |
|
|
|
15.1 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.2 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.3 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.4 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.5 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.6 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
16 (Temperature Rise Test) |
- |
|
|
|
17 (Temperature Rise Test) |
- |
|
|
|
18 (Resistance to heat) |
- |
|
|
|
19 (Resistance to abnormal heat fire and tracking) |
- |
|
|
|
19.2 (Resistance to abnormal heat fire and tracking) |
- |
|
|
|
19.3 (Resistance to abnormal heat fire and tracking) |
- |
|
|
|
20.1 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
20.2 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
20.3 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
21.1 (CREEPAGE DISTANCE AND CLEARANCES) |
- |
|
|
|
22.1 (Resistance to Excessive residual Stress and to Rusting ) |
- |
|
|
|
22.1 (Resistance to Excessive residual Stress and to Rusting ) |
- |
|
|
|
22.1 (Resistance to Excessive residual Stress and to Rusting ) |
- |
|
|
|
|
Partial
|
|
- |
- |