Search by IS Number
Reset
11241 Results
S.No. Lab Name Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
11221 BIS, Guwahati Branch Laboratory (GBL) IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) - - View breakup
-
- -
Mech- Except Y groove crackability, Impact test, NDT, grain size
11222 BIS, Guwahati Branch Laboratory (GBL) IS 1659 (2004) Block boards - Specification (Fourth Revision) MR/BWP - View breakup
Rs 5900/- for BWR Grade, Rs.6800/- for MR grade
- -
-
11223 BIS Patna Branch Laboratory (PBL) IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) - - View breakup
-
- -
All test facilities are available as per the IS except- i. Y-Groove Test (Clause 13) ii. Bend Test for thickness above 25 mm (Clause 11) iii. Tests for microalloying elements and Cr, Mo, Ni, Cu Al and B (Clause 8.2) Note: Prepared test piece of size 55 mm x10 mm x10 mm is required for Impact Test (Clause 12) *- The exact sample type, size and quantity may be ascertained from the latest product manual issued by BIS.
11224 BIS Patna Branch Laboratory (PBL) IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) - - View breakup
-
- -
All test facilities are available as per the IS except- i. Bond/Pull Out Test (Clause 5.7) ii. Total Elongation at Maximum Force (Clause 8.1 and Table 3) iii. Tensile Test of Sizes > 16mm (Clause 8.1 and Table 3) iv. Tests for microalloying elements (Ti, Nb, B, V), Cr, Mo, Cu, Ni and Al (Clause 4.2)
11225 BIS Patna Branch Laboratory (PBL) IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
All test facilities are available as per the IS except Transverse Strength Test (Clause 7 and Table-2) which is an optional test
11226 BIS Patna Branch Laboratory (PBL) IS 1659 (2004) Block boards - Specification (Fourth Revision) - - View breakup
-
- -
All test facilities are available as per the IS
11227 BIS Patna Branch Laboratory (PBL) IS 303 (1989) Plywood for General Purposes - - Rs 4000/- /BWR Grade, Rs.4900/- for MR Grade View breakup
-
- -
All test facilities are available as per the IS
11228 BIS Patna Branch Laboratory (PBL) IS 269 (2015) Ordinary portland cement - Specification (Sixth Revision) - - View breakup
-
- -
All test facilities are available as per the IS except Transverse Strength Test (Clause 7 and Table-3) which is an optional test
11229 BIS Patna Branch Laboratory (PBL) IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
All test facilities are available as per the IS except Transverse Strength Test (Clause 7 and Table 2) which is an optional test
11230 BIS Patna Branch Laboratory (PBL) IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) - - View breakup
-
- -
All test facilities available except Effect on Water (Clause 9.7)
11231 BIS, Eastern Regional Laboratory (ERL) IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Mech-Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement required as per Table 1, Confirmation for testing Alkali Content required.
11232 BIS, Eastern Regional Laboratory (ERL) IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) All varieties - View breakup
-
- -
Mech- Facility not available for- Hydraulic test, Slow Crack Growth Rate and Internal Pressure Creep Rupture test. Fused pipes required to be provided for T/S of butt fusion joints. Chem- Facility available
11233 BIS, Eastern Regional Laboratory (ERL) IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
Mech- Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement (as per Table 1) and declaration of fly ash content & Confirmation for testing Alkali Content required.
11234 BIS, Eastern Regional Laboratory (ERL) IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) Complete for Category 01- up to & including 400 sq mm - View breakup
-
- -
Chem- Facility available for Cu purity only,Gr to be declared. Elect- Cat -01, 02 (Facility not available for- Loss of mass above 1.2 mm, Tensile & Elongation above 2.0 mm thickness.) Cat- FR, FR-LSH-( Facility not available for- oxygen index, temp. index test, Smoke Density Tests). Chem- Facility available for Cu purity only,Grade/class to be declared
11235 BIS, Central Laboratory (CL) IS 13334 : Part 1 (2014) Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) - - View breakup
-
- -
500 gm x 3
11236 BIS, Western Regional Laboratory (WRL) IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) - - View breakup
Rs 16740/- Excluding Pull Out Test and micro-alloying elements
- -
Test facilities are not available for the following: (1) Total elongation at maximum force, (2) Pull out test (Type test) (3) Sizes above 25 mm, (4) Micro-alloy/low alloys, Nb, V, B and Ti, Cr, Cu, Ni, Mo, Nirogen and nitrogen binding elements, like Nb, V, Ti, Al
11237 BIS, Bengaluru Branch Laboratory (BNBL) IS 2347 (2017) Domestic pressure cooker - Specification (Sixth Revision) - - View breakup
-
- -
Except Material Testing
11238 BIS, Bengaluru Branch Laboratory (BNBL) IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
Expect Transverse Strength
11239 BIS, Bengaluru Branch Laboratory (BNBL) IS 269 (2015) Ordinary portland cement - Specification (Sixth Revision) 33 GR 43GR 53 GR - View breakup
-
- -
Expect Transverse Strength
11240 BIS, Central Laboratory (CL) IS 303 (2024) Plywood for General Purposes — Specification (Fourth Revision) - Rs 4000/- /BWR Grade, Rs.4900/- for MR Grade View breakup
-
- -
Facility not available: Static bending strength above 15 mm thickness. ; Excluding- Steady State Formaldehyde Emission Test (Cl. 11.7)
11241 BIS, Guwahati Branch Laboratory (GBL) IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) Up to nominal dia of 25 mm - View breakup
-
- -
Mech- except Pull out test & Tensile,Yield Strength/Elongation up to nominal dia of 25 mm,

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in